From $855
Request an Explosion-Proof Emergency Lighting Quote
Need emergency lighting for a classified industrial facility, chemical processing plant, or hazardous work area?
Request a Quote or call 844-533-7767 for product pricing and technical assistance.
Please provide your hazardous-location classification, gas or dust group, supply voltage, installation requirements, and project specifications.
Explore our LED Explosion-Proof Lighting solutions for additional hazardous-location lighting equipment.
The LEDSION LS-ES03C1 Explosion-Proof LED Emergency Light is designed to provide emergency illumination in hazardous industrial locations requiring appropriately classified electrical equipment. Featuring two independently adjustable LED spotlights and a three-hour emergency operating duration, this wall-mounted fixture supports emergency lighting applications in Class I Division 1, Class I Division 2, Class II, and Class III environments, subject to the specified classifications.
Constructed with an A360 die-cast aluminum housing and stainless steel hardware, the LS-ES03C1 combines 120–277V AC input, UL 924 emergency-lighting compliance, UL 844 hazardous-location compliance, and IP66 protection. As part of our selection of explosion-proof exit signs and emergency lighting, this fixture features adjustable spotlight heads that allow illumination to be directed toward designated emergency routes, equipment access areas, and other locations identified in the facility’s emergency lighting plan.
Class I Division 1 Emergency Lighting for Hazardous Locations
The LS-ES03C1 is intended for classified industrial environments where conventional emergency lighting equipment may not be suitable.
The manufacturer identifies the following hazardous-location classifications:
| Hazardous-Location Classification | Groups |
|---|---|
| Class I, Division 1 | C, D |
| Class I, Division 2 | A, B, C, D |
| Class II, Division 1 | E, F, G |
| Class II, Division 2 | F, G |
| Class III | Listed by manufacturer |
Class I Division 1 Groups C and D cover specified flammable gas or vapor environments where appropriately certified equipment is required.
The fixture is also identified for combustible-dust environments under Class II and for Class III locations.
The correct fixture selection must account for the actual area classification, material group, temperature code, and applicable electrical installation requirements.
Important: The LS-ES03C1 is not identified for Class I Division 1 Groups A or B. Its Class I Division 2 Groups A–D classification must not be confused with its Class I Division 1 rating.
Three-Hour Emergency Operating Duration
The LS-ES03C1 provides a manufacturer-specified three-hour emergency operating duration.
This extended emergency lighting period is a central feature for facilities requiring backup illumination during interruptions to normal electrical service.
Potential applications include:
-
Chemical processing plants
-
Oil and gas facilities
-
Industrial manufacturing operations
-
Hazardous material handling areas
-
Combustible dust processing facilities
-
Classified equipment rooms
-
Industrial maintenance and service areas
-
Hazardous-location emergency routes
-
Outdoor classified industrial installations
Emergency lighting requirements should be determined from the facility’s applicable life-safety codes, electrical classifications, and emergency lighting design.
Dual Adjustable LED Spotlights
The LS-ES03C1 incorporates two high-output LED spotlight heads.
Each head supports horizontal and vertical aiming adjustments, allowing the installer to direct illumination toward designated areas.
This arrangement can provide flexibility when illuminating:
-
Emergency exit routes
-
Doorways and access points
-
Industrial passageways
-
Equipment access locations
-
Stairway approaches
-
Designated emergency circulation areas
The manufacturer offers 90° and 120° beam-angle options.
The correct optical configuration depends on the required coverage, mounting position, and emergency illumination criteria.
UL 924 and UL 844 Compliance
The manufacturer identifies the LS-ES03C1 as compliant with two important standards:
UL 924 — Emergency Lighting and Power Equipment
Addresses equipment used for emergency lighting applications.
UL 844 — Luminaires for Use in Hazardous (Classified) Locations
Addresses lighting equipment intended for specified hazardous environments.
The manufacturer also lists ETL certification.
These claims are relevant to industrial buyers specifying emergency lighting for classified areas.
Before final project approval, the applicable NRTL certification record, hazardous-location marking, and temperature code should be verified for the supplied model.
Durable Construction for Industrial Environments
The LS-ES03C1 uses an A360 die-cast aluminum enclosure with stainless steel hardware.
Additional manufacturer-listed features include:
-
IP66 ingress protection
-
NEMA 4X enclosure rating
-
IK10 impact resistance
-
Suitable for wet locations
-
Hinged access door
-
3/4-inch NPT conduit hubs
-
Operating temperature range of -20°C to +60°C
-
50,000-hour stated service life
-
Five-year limited warranty
These construction features support installation in demanding industrial environments where moisture, dust, and mechanical exposure must be considered.
Wall-Mounted Installation with Adjustable Light Heads
The LS-ES03C1 is designed for wall mounting.
The manufacturer identifies a mounting-hole center distance of 251 mm (9.88 inches) and specifies the use of suitable mounting hardware.
The fixture includes 3/4-inch NPT conduit entry provisions.
Its hinged enclosure provides access for wiring and maintenance, while the adjustable spotlight heads can be aimed after the unit is secured.
Installation must follow the manufacturer’s instructions and applicable hazardous-location electrical requirements, including appropriate conduit sealing, wiring methods, and enclosure integrity.
120–277V AC Input
The LS-ES03C1 operates on 120–277V AC.
This input range accommodates common commercial and industrial electrical systems.
The manufacturer does not identify a 347–480V input option in the supplied specification.
For facilities using higher-voltage distribution systems, the emergency lighting circuit and fixture supply voltage must be evaluated before ordering.
Emergency Lighting as Part of an Industrial Lighting System
Hazardous-location emergency lights serve a different purpose from normal-operation high bays, linear fixtures, floodlights, and other facility luminaires.
For chemical plants, manufacturing facilities, and processing operations, the LS-ES03C1 can complement other industrial lighting fixtures as part of a coordinated facility lighting and emergency preparedness plan.
Emergency lighting should be evaluated independently for required illumination, backup duration, electrical classification, and applicable life-safety requirements.
LS-ES03C1 Technical Specifications
| Specification | Details |
|---|---|
| Manufacturer | LEDSION Lighting |
| Model | LS-ES03C1 |
| Product Type | Explosion-Proof LED Emergency Light |
| Emergency Operation | 3 Hours |
| Light Heads | Two Adjustable LED Spotlights |
| Beam Angles | 90° / 120° |
| Input Voltage | 120–277V AC |
| Color Temperature | 3000K–6500K |
| Class I Division 1 | Groups C, D |
| Class I Division 2 | Groups A, B, C, D |
| Class II Division 1 | Groups E, F, G |
| Class II Division 2 | Groups F, G |
| Class III | Manufacturer Listed |
| Emergency Lighting Standard | UL 924 |
| Hazardous-Location Standard | UL 844 |
| Certification | ETL, per manufacturer |
| Enclosure Rating | NEMA 4X |
| Ingress Protection | IP66 |
| Impact Rating | IK10 |
| Wet Location | Suitable |
| Housing | A360 Die-Cast Aluminum |
| Hardware | Stainless Steel |
| Mounting | Wall |
| Conduit Entries | 3/4-inch NPT |
| Operating Temperature | -20°C to +60°C |
| Stated Service Life | 50,000 Hours |
| Net Weight | 8 kg / 17.64 lb |
| Approximate Overall Height | 320.5 mm / 12.6 in |
| Housing Width | 280 mm / 11 in |
| Approximate Depth | 165.5 mm / 6.5 in |
| Warranty | 5-Year Limited |
Buyer Questions: Selecting the LS-ES03C1 Emergency Light
Can this fixture be used in Class I Division 1 locations?
Yes, for the manufacturer’s specified Class I Division 1 Groups C and D classifications. It is not identified for Class I Division 1 Groups A or B.
Does the emergency light operate for three hours?
The manufacturer specifies a three-hour emergency operating duration. Actual performance and required testing should be confirmed as part of the installation and maintenance program.
Can the two spotlight heads be adjusted independently?
Yes. Both heads provide horizontal and vertical aiming adjustment.
Is the LS-ES03C1 suitable for outdoor installation?
The manufacturer identifies the fixture as outdoor-rated, suitable for wet locations, IP66-rated, and NEMA 4X.
Can the fixture operate on 277V?
Yes. The specified input range is 120–277V AC.
Is this a replacement for standard explosion-proof lighting?
No. The LS-ES03C1 is intended for emergency illumination. Normal-operation lighting requirements must be addressed separately.
Get the Right Explosion-Proof Emergency Lighting for Your Facility
Emergency lighting in hazardous industrial locations requires careful coordination between electrical-area classification, emergency operating duration, fixture placement, and life-safety requirements.
Whether you’re upgrading emergency lighting in a chemical processing facility, specifying equipment for a Class I Division 1 area, or replacing existing hazardous-location emergency fixtures, LED PROS WorldWide can help evaluate the LS-ES03C1 for your project.
Provide your hazardous-location classification, gas or dust group, supply voltage, mounting information, and emergency lighting specifications.
Request a Quote or call 844-533-7767 for product pricing and technical assistance.
Frequently Asked Questions
What is a Class I Division 1 explosion-proof emergency light?
It is emergency lighting equipment designed and certified for specified hazardous locations where flammable gases or vapors may be present under the conditions defined by the area classification.
What is the emergency runtime of the LS-ES03C1?
The manufacturer specifies three hours.
Which Class I Division 1 groups are supported?
Groups C and D.
Does the fixture support Class II Division 1?
Yes. The manufacturer lists Class II Division 1 Groups E, F, and G.
Are the spotlight heads adjustable?
Yes. Both heads provide horizontal and vertical adjustment.
What voltage is required?
120–277V AC.
Is the fixture UL 924 compliant?
The manufacturer states compliance with UL 924 and identifies ETL certification. Verify the applicable certification record for project approval.
What environmental ratings are provided?
IP66, NEMA 4X, IK10, and wet-location suitability.
What is the warranty?
The manufacturer specifies a five-year limited warranty.
Stay Connected with Our Lighting Resources
Add IndustrialLightingFixtures.org as a Preferred Source on Google to see more of our lighting guides and technical resources across Google Search experiences.
Related Resources
LED Explosion-Proof Lighting — Explore hazardous-location lighting equipment for classified industrial environments.
Explosion-Proof Lighting Standards & Selection Guide — Review hazardous-location classifications, certification considerations, and fixture selection requirements.
Industrial Lighting Fixtures — Explore industrial lighting solutions for manufacturing, processing, and other commercial facilities.