Class 1 Division 2 LED Lighting are robust, durable industrial flood lights engineered for hazardous locations and high particulate areas such as granaries, mills, and mines, locations with gasoline vapors like gas stations, airplane hangars, or auto shops, and environments where petrochemical vapors exist. see The Safe Choice – Explosion Proof High Bay Lighting.

Hazardous locations or areas where flammable gases or vapors are/could become present in concentrations suitable to produce explosive and/or ignitable mixtures. Choose LED Explosion Proof Lighting from the experts at LED Pros WorldWide

What is a Class 1 Division 2: One of the following three situations must exist in order for an area to be considered a Class 1 Division 2 location;

a. An area where flammable liquids and gases are handled, but not expected to be in explosive concentrations. However, the possibility for these concentrations to exist might occur if there was an accidental rupture or another unexpected incident.
b. An area where ignitable gases or vapors are normally prevented from accumulating by positive mechanical ventilation, yet could exist in ignitable quantities if there was a failure in the ventilation systems.
c. Areas adjacent to Class 1 Division 1 location where it is possible for ignitable concentrations of gas/vapors to come into this area because there isn’t proper ventilation.

For C1 and Div 1 fixtures, see Class 1 Division 1 LED Lighting – Looking to replace your traditional explosion-proof flood lighting with brighter, more energy-efficient LED? Call for special pricing today toll-free 1-844-LED PROS (1-844-533-7767)  

Class 1 Division 2 LED Lighting

Explosion Proof High Bay LED Light - Type A

LED Explosion Proof High Bay Lighting – Type A

High Bay Flood Light, Marine, and Wet Locations; available in 60/80/100/150/200/250/300/400W; Call for today’s special price!

   
Class 1 Division 2 LED Lighting

Class 1 Division 2 LED Lighting – B Series

Uses; Flood Lights; Spotlight, Tunnel Light, Downlight, Choose Spherical Glass Diffuser with a wire cage, Optional Wire Guard, Dome Reflector, Angle Reflector; Up to 8100 lumens @ 60W; 100-277/200-480VAC; Marine and Wet Locations; 10.6″ round; available in 20W/40W/60/80/100/120W/150W/200W; Call for today’s special price!

   
Marine Explosion Proof Lights

Marine Explosion Proof Lights –  Type FLF

Low Bay Linear; 5 different lengths; for marine environments; rugged, salt water, corrosive elements; design to shed water; 14.5″ to 61.8″; up to 14,000 lumens @ 100W; 10/20/30/40/50/60/70/80/90/100W; Call for today’s special price!

   
Explosion Proof LED Linear Lighting

Explosion Proof LED Linear Lighting – H Series

Uses; Low Bay; 2ft and 4ft options; uses; spot light, down light and tunnel light; Up to 8100 lumens @ 60W; 100-277/200-480VAC; 23.62″ X 3.3″; available in 10W/20W/30W/40W/50W/60W; Call for today’s special price!

   
Class 1 Div 2 Lighting

Class 1 Div 2 Lighting-Q Series

Round low bay lighting with motion sensor;  Class 1, Division 2, Groups A,B,C,D; Class 2, Division 1, Groups E,F,G; 20W/40W/60W/80W/100W/150W/200W; up to 28,000 lumens; 100-277/200-480V; Call for today’s special price

   
Explosion Proof LED Linear Lighting

Explosion Proof LED Linear Lighting –  R Series

2ft, 4ft nominal lengths; Ratings IP 66, IK 10; available in30/50W; Prices start at $

   
Explosion Proof Lighting S Series

Class 1 Division 2 LED Lighting –  S Series

Round Low bay area light with Adaptor Lamppost Mounting, Ceiling Bracket Mounting, Pole Mounting; Class l, Division ll, Groups A,B,C,D; up to 28,000 lumens; 20W/40W/60W/80W/100W/150W/200W; 100-277/200-480V; Call for today’s special price

   
Class 1 Division 2 LED Lighting

Class 1 Division 2 LED Lighting – Area Light STA 

Pole or wall-mounted outdoor area lighting in hazardous locations; up to 42,000 lumens; available in 100/150/200/300W; Call for today’s special price!

   
Class 1 Division 2 Lighting Fixtures

Class 1 Division 2 Lighting Fixtures -AMLG series

LED Floodlight for Hazardous Locations; Marine Outside Type (Salt Water); Wet Locations; Enclosed and gasket fixtures; Ideal for Locations requiring dependable, consistent lighting in extreme hot/cold temperature environments. (-40 °F to +149 °F) ambient temperature range; Available in 70/110/150W; Made in the USA; Call for today’s special price!

   
Class 1 Division 2 LED Linear Lighting

Class 1 Division 2 LED Linear Lighting – IR1 series

LED Linear – 2ft, 4ft models; Ideal for marine wet & damp locations; corrosion-resistant fixture; Petrochemical Facilities, Lubrication Pits, Oil Drilling Rigs, Crew Quarters, Solvent/Cleaning Areas, Processing Plants, Water Treatment Areas, Marine Loading Docks; Available in 17/35/40/54/60W; Made in the USA; Call for today’s special price!

   
Class 1 Div 2 LED Linear Lighting

Class 1 Div 2 LED Linear Lighting – IR2 series

LED Linear – 2ft, 4ft models; Ideal for marine wet & damp locations; corrosion-resistant fixture; Petrochemical Facilities, Lubrication Pits, Oil Drilling Rigs, Crew Quarters, Solvent/Cleaning Areas, Processing Plants, Water Treatment Areas, Marine Loading Docks; Made in the USA; Call for today’s special price!

   
Class 1 Div 2 LED Linear Lighting

Class 1 Div 2 LED Linear Lighting – IR3 series

UL 1598A Outdoor Marine Type (Saltwater); Meets Coast Guard Specifications; Enclosed and gasket; Corrosion resistant, marine grade, copper-free extruded aluminum; Made in USA; Call for today’s special price!

   
Painting Spray Booth Lights

Painting Spray Booth Lights – IR4 series 

Paint spray booth approved; LED linear – 2ft, 4ft models; Corrosion resistant, marine grade, copper-free aluminum, heavy gauge extruded reflectors with high gloss reflective finish; Available in 17/ 35/40/54/60W; Made in USA; Call for today’s special price!

   
Class 1 Div 2 LED Lighting

Class 1 Div 2 LED Lighting – Ledsion

features a die-casting aluminum housing, anti-corrosion painting IP68; 10KV surge protection; UL certified housing, suitable for marine applications; Zone1 & Zone2 gaseous environment, Zone 1 & Zone 2 dust environment; Class 1 Division 2 Group A, B, C, D; Optional Photocell / Surge protector/ Motion sensor; available in 100/200W; Call for today’s special price!

   
Class 1 Division 2 LED Spotlights

Class 1 Division 2 LED Spotlights – J series

LED hazardous location flood light – UL844 (American): Class 1 Division 2 Group A, B, C, D, UL1598 Luminaries: UL1598A Marine; UL8750; CSA C22.2 No. 137-M1981; available in 20/30/40/60/80/100/120/150/180/200W; Call for today’s special price!; Call for today’s special price!

   

Class I, Division 2 rated lighting fixtures are designed to be used in hazardous or explosive areas. They are equipped with safety features to minimize the risk of starting an explosion or ignition of a combustible atmosphere. Class I, Div 2 lights are typically found in industrial applications such as oil refineries, chemical factories, pipelines, wastewater treatment plants, gas plants, and other locations where combustible gas is present.

The main safety features of Class I, Division 2 fixtures include:

• At least one self-closing pressure switch that will automatically shut off the light if the pressure in the hazardous atmosphere changes

• A spark-resistant housing and wiring to reduce the risk of sparks that could cause an explosion

• A watertight, dust-tight, and corrosion-resistant enclosure to keep contaminants away from the electrical components

• A thermally protected lamp to prevent overheating that could cause sparks

• A ground fault circuit interrupter to detect and shut off a light if there is any current leakage from the hot wire to ground

• Accessible external wiring that is clearly marked to prevent incorrect connections

• An intrinsically safe circuit design that limits the current and potential energy to harmless levels

• Certification from a Nationally Recognized Testing Laboratory (NRTL) that tests and verifies that the fixture is compliant with applicable safety standards

Class I, Div 2 LED fixtures are a vital part of many explosive environments, and they provide the necessary safety features to help prevent accidents and explosions.

 

Class 1 Div 2 LED Lighting for hazardous locations

 

FAQs About Class 1 Div 2 Lighting

Class 1 Division 2 lighting is a type of hazardous area lighting that is certified for use in hazardous locations that are classified as Class 1 Division 2. This classification is based on the National Electric Code (NEC) and is used to identify areas where there is the potential for an explosive gas mixture to exist. Class 1 Division 2 lighting is specifically designed for use in areas where dangerous flammable gases, vapors, and dusts are present.

Q1. What is Class 1 Division 2 Lighting?
A1. Class 1 Division 2 Lighting is a type of hazardous area lighting that is certified for use in hazardous locations that are classified as Class 1 Division 2. This classification is based on the National Electric Code (NEC) and is used to identify areas where there is the potential for an explosive gas mixture to exist.

Q2. What areas require Class 1 Division 2 lighting?
A2. Class 1 Division 2 lighting is specifically designed for use in areas where dangerous flammable gases, vapors, and dusts are present. Examples of such areas include chemical processing, petrochemical, engine rooms, fuel storage and transfer areas, spray booths, and paint-drying booths.

Q3. What are the benefits of using Class 1 Division 2 lighting?
A3. Class 1 Division 2 lighting is advantageous because it is designed to provide reliable, safe illumination in hazardous locations where there is the potential for an explosive gas mixture to exist. It provides better illumination by producing less heat, which reduces the potential for sparks and is therefore more reliable and safer than standard lighting. Additionally, Class 1 Division 2 lighting is designed to prevent explosions and fires in hazardous locations by

Q4. What is a “hazardous” location?
A4. hazardous location is defined as an area where a specific hazard exists, either from flammable gases, vapors, combustible dusts, or ignitable fibers or flyings. The NEC outlines three classes of hazardous locations; Class I, II, and III. Class I locations are areas where flammable gases, vapors, or liquids exist in the air in quantities sufficient to create an explosive or ignitable mixture. Class II locations are areas where ignitable dusts, fibers, and flyings are present in a quantity sufficient to create a fire or explosion hazard when suspended in air. Class III locations are areas where easily ignitable fibers and flyings are present, but the dusts are not likely to be suspended in air in sufficient quantities to ignite or explode.

Q5. What makes C1D2 lighting different from other types of lighting?
A5. C1D2 lighting is designed and tested to meet strict criteria for creating a safe environment even in hazardous area applications. This includes features like corrosion and temperature resistance, vibration and shock resistance, explosion-proof and dust-ignition proof construction, and UL/cUL/ATEX/IECEx certification. The NEC and other safety regulations specify that certain types of equipment must be installed in hazardous locations.

Q6. Can a light pole be used in Class 1 Division 2?
A6. Yes, here at LED Pros we offer several Class 1 Div 2 fixtures with pole mounting options; Slip fitter mounts, Arm mounts, and Pole mounting brackets.

 

Class 1 Div 2 LED Lighting for hazardous locations

 

At LED Pros Worldwide, we can supply you with everything you may need so that you can have the lights that perform well, last for a long time, and give you the safe and secure environment patrons want the most. You can find out more about industrial lighting fixtures and see all the choices we have available for you when you come to our website and look at our selection. You will find that all our products are expertly crafted and provide you with the energy-saving and efficient alternatives you want most. When you are ready to place an order, or if you have any questions about your lighting needs, just call us at 844) 533-7767 and we will be glad to assist you.

Buy Direct and Save $$$ – All of our lighting fixtures ship factory direct to your facility. Call sales toll-free (1-844-533-7767) 

 

Contact

  • LED Pros Worldwide does not share your information.