LEDSION round explosion-proof UFO LED high bay fixture with industrial aluminum housing, tempered glass lens, and adjustable mounting bracket for hazardous locations

Prices start at $460

Request an Explosion-Proof UFO High Bay Quote

Need hazardous-location high bay fixtures for a manufacturing facility, chemical processing plant, wastewater treatment operation, or industrial project?

Request a Quote or call 1-844-533-7767 for pricing, availability, and technical assistance.

Include the required quantity, mounting height, operating voltage, hazardous-location classification, preferred wattage, and mounting configuration.

Explore our LED explosion-proof lighting fixtures for additional hazardous-location lighting options.

The LEDSION Explosion-Proof UFO LED High Bay Lights provide high-output illumination for industrial environments where flammable gases, combustible dust, or other hazardous materials require appropriately classified electrical equipment. Available in 150W, 200W, and 300W configurations, these round industrial luminaires combine durable aluminum construction, tempered glass optics, and multiple mounting options for demanding facility lighting applications.

Designed for use in classified industrial environments, these fixtures support applications in petrochemical processing, wastewater treatment, manufacturing, offshore facilities, and heavy industrial operations. As part of our selection of Class I Division 2 LED lighting fixtures, the UFO high bay configurations offer different wattage and hazardous-location classification options to accommodate facility-specific requirements. 

High-Output LED Lighting for Hazardous Industrial Locations

The LEDSION UFO-style luminaires provide a compact, round lighting configuration for overhead industrial installations. Their high-efficiency LED systems help replace conventional high-wattage metal halide or high-pressure sodium fixtures while reducing power consumption and maintenance requirements.

Key features include:

  • Available 150W, 200W, and 300W configurations.

  • Rated output of 19,500 lumens at 150W and 26,000 lumens at 200W.

  • 300W lumen output pending manufacturer confirmation.

  • 5000K color temperature.

  • 120–277V AC input.

  • IP66-rated protection.

  • Heavy-duty aluminum construction.

  • Tempered glass optical lens.

  • Multiple mounting arrangements.

  • Manufacturer-listed hazardous-location certifications.

  • Five-year limited warranty.

Hazardous-Location Classifications

Selecting the correct explosion-proof luminaire requires matching its certified classifications to the actual installation environment.

150W and 200W B3 Series

The manufacturer identifies compliance with:

  • Class I, Division 2, Groups A, B, C, and D.

  • Class II, Division 1, Groups E, F, and G.

  • Class II, Division 2, Groups F and G.

  • Class III.

  • Class I, Zone 2, Group IIC.

  • Additional Zone classifications as specified in the manufacturer’s certification documentation.

The B3 Series is also listed by the manufacturer with UL 844, UL 1598, UL 1598A, and UL 924 references. 

300W CES Series

The manufacturer identifies:

  • Class I, Division 2, Groups A, B, C, and D.

  • Class II, Division 2, Groups F and G.

  • Class III.

The 300W specification sheet references UL/cUL certification number E475887.

 

LED Performance and Energy Efficiency

The 150W and 200W B3 Series are rated at 130 lumens per watt. The manufacturer lists 19,500 lumens for the 150W model and 26,000 lumens for the 200W model.

The 300W CES Series lists efficacy above 130 lm/W. 

Model Wattage Rated Lumens Rated Efficacy
EX-150W B3D50D120 150W 19,500 lm 130 lm/W
EX-200W B3D50D120 200W 26,000 lm 130 lm/W
CES-EX-D-GBX-300-50 300W >39,000 Above 130 lm/W stated

Construction, Environmental Protection, and Optical Performance

150W–200W B3 Series

The B3 Series uses a copper-free aluminum housing, tempered glass diffuser, and stainless steel hardware. The manufacturer lists IP66 protection, with IK08 protection for the glass-cover configuration and IK10 for the wire-guard configuration.

The operating-temperature range is listed as −40°F to 131°F. The manufacturer also identifies L70 lumen maintenance exceeding 150,000 hours at 55°C, subject to the stated conditions.

300W CES Series

The CES Series uses a heavy die-cast aluminum alloy housing with black powder-coated finish and tempered glass optics. The manufacturer identifies IP66 protection, 6kV surge protection, a Mean Well LED driver, and an operating-temperature range of −40°C to +60°C.

 

Electrical Requirements and Controls

All three wattage configurations use 120–277V AC input.

The 150W and 200W B3 Series offers optional 0–10V dimming. Battery backup is also described as available, but its specifications and operating duration are not provided in the supplied sheets.

The 300W CES Series lists a 0.9 power factor and a 6kV surge-protection feature. Dimming capability is not confirmed in its supplied data sheet.

For projects requiring emergency operation, dimming controls, or other special electrical features, verify the exact model configuration before ordering.

Technical Specifications

Specification 150W B3 200W B3 300W CES
Manufacturer LEDSION LEDSION LEDSION
Model EX-150W B3D50D120 EX-200W B3D50D120 CES-EX-D-GBX-300-50
Rated Power 150W 200W 300W
Lumen Output 19,500 lm 26,000 lm Verify
Efficacy 130 lm/W 130 lm/W Above 130 lm/W stated
CCT 5000K 5000K 5000K
CRI Greater than 72 Greater than 72 Greater than 72
Input Voltage 120–277V AC 120–277V AC 120–277V AC
Power Factor 0.95 0.95 0.9
Beam Distribution 120° 120° Verify photometric file
Housing Copper-free aluminum Copper-free aluminum Aluminum alloy
Lens Tempered glass Tempered glass Tempered glass
Ingress Protection IP66 IP66 IP66
Impact Protection IK08 / IK10, configuration-dependent IK08 / IK10, configuration-dependent 4J impact resistance stated
Class I Div 2, Groups A–D Div 2, Groups A–D Div 2, Groups A–D
Class II Div 1 E–G; Div 2 F–G Div 1 E–G; Div 2 F–G Div 2 F–G
Class III Listed Listed Listed
Operating Temperature −40°F to 131°F −40°F to 131°F −40°C to +60°C
Dimming Optional 0–10V Optional 0–10V Not specified
Battery Backup Optional; details to confirm Optional; details to confirm Not specified
Warranty 5 years 5 years 5 years

Buyer Questions

Which model is appropriate for a Class II Division 1 location?

The manufacturer lists Class II Division 1, Groups E, F, and G for the 150W and 200W B3 Series. The 300W CES Series is identified only for Class II Division 2, Groups F and G.

Can the 300W model replace a 1000W metal halide fixture?

The manufacturer describes the 300W model as a replacement candidate for 600–1000W metal halide or high-pressure sodium fixtures. Actual suitability depends on the required illumination, mounting height, optics, and confirmed lumen output.

Are these fixtures suitable for marine environments?

The B3 Series includes manufacturer-listed UL 1598A marine-outside-type compliance. Confirm the applicable certification and environmental suitability for the project.

Can the fixtures be dimmed?

Optional 0–10V dimming is listed for the 150W and 200W B3 models. The supplied 300W documentation does not establish dimming compatibility.

Are mounting accessories included?

Different mounting configurations are illustrated by the manufacturer. Confirm which brackets, junction boxes, and accessories are included in the quotation.

Need Explosion-Proof UFO High Bay Lighting for Your Facility?

LED PROS WorldWide assists contractors, facility managers, engineers, and purchasing departments with hazardous-location lighting selection and project quotations.

Whether your project involves chemical processing, wastewater treatment, manufacturing, or industrial infrastructure, the correct wattage, mounting arrangement, and certified hazardous-location classification are essential.

Request a Project Quote or call 1-844-533-7767.

Please provide the required fixture quantity, mounting height, operating voltage, hazardous-location classification, and any project-specific certification requirements.

Frequently Asked Questions

What wattages are available?

The supplied LEDSION models include 150W, 200W, and 300W configurations.

Are these Class I Division 1 fixtures?

No. The supplied manufacturer sheets identify Class I Division 2 classifications. They do not establish Class I Division 1 approval.

Which fixtures are rated for Class II Division 1?

The 150W and 200W B3 Series are listed by the manufacturer for Class II Division 1, Groups E, F, and G.

What voltage do these fixtures require?

All three models use 120–277V AC input.

Are the fixtures waterproof?

The manufacturer lists IP66 protection. This does not establish suitability for continuous submersion.

What color temperature is available?

The supplied configurations are listed at 5000K.

What is the warranty?

The manufacturer lists a five-year limited warranty.

Can these fixtures be used in chemical plants?

They may be suitable for chemical processing applications when their exact certified classifications match the facility’s documented hazardous-location requirements.

Stay Connected with Our Lighting Resources

Add IndustrialLightingFixtures.org as a Preferred Source on Google to see more of our lighting guides and technical resources across Google Search experiences.

Related Resources

LED Explosion-Proof Lighting — Explore hazardous-location lighting fixtures for chemical processing, manufacturing, wastewater treatment, and other classified industrial environments.

Explosion-Proof Lighting Standards & Selection Guide — Review hazardous-location classifications, certification requirements, and considerations for selecting explosion-proof LED fixtures.

Industrial Lighting Fixtures — Explore industrial lighting solutions for manufacturing facilities, processing plants, warehouses, and commercial infrastructure.

0/5 (0 Reviews)

Write a Product Review

Your email address will not be published. Reviews are manually approved before publication. Please submit a review based on your actual experience.

This site uses Akismet to reduce spam. Learn how your comment data is processed.