From $300
Request a Class I Division 2 LED High Bay Quote
Specifying hazardous-location lighting for a chemical processing plant, wastewater treatment facility, refinery, manufacturing operation, or other classified industrial environment?
Request a Quote or call 1-844-533-7767 for commercial pricing, availability, and technical product assistance.
Include the required hazardous-location classification, wattage, mounting method, voltage, and fixture quantity.
Explore our Class I Division 2 LED lighting fixtures for additional hazardous-location lighting solutions.
The CES-EX-GB-02 Explosion-Proof LED High Bay Light Series provides compact, energy-efficient illumination for industrial facilities requiring certified hazardous-location lighting. Available in 30W, 40W, 60W, and 80W configurations, these round LED fixtures feature Bridgelux 3030 LEDs, Meanwell drivers, a 120° beam distribution, and corrosion-resistant aluminum alloy construction. The series is designed for demanding environments where moisture, vibration, combustible dust, or hazardous gases may affect lighting equipment.
Engineered for Class I Division 2, Class II Division 2, and Class III locations, the CES-EX-GB-02 Series also carries ATEX, IECEx, and marine-related certification references. Its compact housing, tempered glass lens, and multiple mounting accessories make it a versatile addition to our Class I Division 2 explosion-proof LED lighting selection for industrial processing, manufacturing, wastewater treatment, and marine facilities.
Compact Explosion-Proof LED High Bay Lighting
The CES-EX-GB-02 Series combines a compact circular housing with industrial-grade electrical components and hazardous-location protection.
The smaller 30W and 40W fixtures are suitable for applications requiring moderate light output, while the 60W and 80W models provide additional illumination for larger work areas.
Key Features
-
Four wattages: 30W, 40W, 60W, and 80W.
-
Bridgelux 3030 LED chips.
-
140 lm/W efficacy listed in the technical specifications.
-
120° beam angle.
-
100–277V AC, 50/60Hz.
-
Meanwell LED driver.
-
Power factor greater than 0.95.
-
Total harmonic distortion below 10%.
-
Class I Division 2, Groups A, B, C, and D.
-
Class II Division 2, Groups F and G.
-
Class III hazardous-location classification.
-
ATEX and IECEx certification references.
-
UL 844, UL 1598, and UL 1598A marine-related listings.
-
Corrosion-resistant ADC12 aluminum alloy housing.
-
8–10 mm tempered glass lens.
-
Shock- and vibration-resistant construction.
-
Curved-fin heat dissipation design.
-
4kV/6kV surge protection design.
-
50,000-hour L70 rated life.
-
Seven mounting accessory configurations.
-
Five-year manufacturer warranty.
Four Wattage Options for Industrial Applications
The CES-EX-GB-02 Series is available in four configurations.
| Model | Wattage | LED Efficacy | Nominal Lumens* |
|---|---|---|---|
| CES-EX-GB-02-30 | 30W | 140 lm/W | 4,200 lm |
| CES-EX-GB-02-40 | 40W | 140 lm/W | 5,600 lm |
| CES-EX-GB-02-60 | 60W | 140 lm/W | 8,400 lm |
| CES-EX-GB-02-80 | 80W | 140 lm/W | 11,200 lm |
Nominal lumen values are calculated from the manufacturer’s stated 140 lm/W efficacy. The data sheet does not provide independently measured lumen output for each wattage.
30W and 40W Compact Fixtures
The 30W and 40W models feature a 200 mm diameter housing.
These configurations are appropriate for smaller industrial work areas, equipment platforms, maintenance locations, and other applications where a compact hazardous-location luminaire is preferred.
60W and 80W Higher-Output Fixtures
The 60W and 80W models feature a larger 300 mm diameter housing.
These configurations support applications requiring additional illumination across industrial production areas, service platforms, and equipment installations.
Class I Division 2 Hazardous-Location Certification
The CES-EX-GB-02 Series is identified for classified industrial environments involving hazardous gases, combustible dust, and ignitable fibers.
Class I Division 2 — Groups A, B, C, and D
The manufacturer identifies the series for Class I Division 2 locations involving flammable gases and vapors.
These classifications are relevant to designated areas within chemical processing plants, refineries, petrochemical facilities, and industrial manufacturing operations.
Class II Division 2 — Groups F and G
The series is also specified for Class II Division 2 environments involving combustible dust.
Potential applications include classified processing, manufacturing, and material-handling areas.
Class III
The manufacturer lists Class III hazardous-location classification for environments involving ignitable fibers or flyings.
UL and CSA Certification References
The manufacturer’s certification section identifies:
-
UL 844 — Hazardous-location luminaires.
-
CSA C22.2 No. 137.
-
CSA C22.2 No. 250.0.
-
Certification reference E475887.
-
UL 1598 — Luminaires for damp and wet locations.
-
Certification reference E357786.
-
UL 1598A — Marine vessels.
-
Certification reference E495071.
The manufacturer also identifies temperature classifications including T4, T4A, T5, and T6, depending on the applicable configuration.
ATEX and IECEx Hazardous-Area Certifications
In addition to North American hazardous-location classifications, the CES-EX-GB-02 Series includes ATEX and IECEx certification references.
ATEX Markings
The manufacturer lists:
-
Ex II 2 D Ex tb IIIC T79°C / T83°C / T89°C Db.
-
Ex II 3 G Ex ec IIC T3 / T4 / T5 Gc.
ATEX certificate references:
-
UL 22 ATEX 2543X Rev. 0.
-
UL 22 ATEX 2544X Rev. 0.
IECEx Markings
The manufacturer lists:
-
Ex ec IIC T4 Gc.
-
Ex tb IIIC T79°C Db.
IECEx certificate reference:
IECEx UL 22.0091X.
These markings support product selection for applicable gas and dust hazardous-area installations.
Corrosion-Resistant Aluminum Alloy Housing
The CES-EX-GB-02 Series uses an ADC12 aluminum alloy housing.
The manufacturer identifies the housing as corrosion resistant and suitable for saltwater and corrosive industrial environments.
Curved-Fin Heat Dissipation
The housing features a curved-fin design intended to maximize heat transfer away from the LED components.
Tempered Glass Lens
The luminaire uses an 8–10 mm tempered glass lens designed to resist shock and vibration.
The manufacturer specifies light transmission greater than 90%.
Protective Wire Guard
The fixture design incorporates a protective wire guard over the glass lens.
Industrial Durability
The combination of aluminum alloy construction, tempered glass, and shock-resistant design supports use in demanding industrial and marine applications.
High-Efficiency Bridgelux LEDs and Meanwell Driver
The CES-EX-GB-02 Series uses Bridgelux 3030 LED chips with a Meanwell power supply.
LED Performance
The manufacturer specifies 140 lm/W in the technical parameter table.
The LED source is identified as LM-80 tested, with low lumen depreciation characteristics.
Meanwell Power Supply
The manufacturer identifies a Meanwell LED driver with driver efficiency greater than 90%.
Power Quality
The series provides:
-
Power factor greater than 0.95.
-
Total harmonic distortion below 10%.
-
100–277V AC input.
-
50/60Hz operation.
Surge Protection
The manufacturer specifies a 4kV/6kV surge protection power-supply design.
120° Wide-Beam LED Distribution
The CES-EX-GB-02 Series provides a nominal 120° beam angle.
This broad distribution supports general illumination of industrial work areas, equipment platforms, and service locations.
The manufacturer’s photometric diagrams show a wide, generally symmetrical light distribution.
The broad beam is particularly relevant to applications where uniform illumination is preferred over concentrated spot lighting.
Industrial Applications
Wastewater Treatment Plants
Wastewater treatment facilities may include classified areas where moisture, corrosive conditions, and hazardous gases require specialized lighting equipment.
The CES-EX-GB-02 provides compact hazardous-location lighting with corrosion-resistant construction.
Oil and Gas Refineries
Refineries may require Class I Division 2 lighting in designated process areas, equipment platforms, and maintenance locations.
Petrochemical Facilities
Petrochemical processing operations can require certified luminaires for hazardous gas environments.
Chemical Processing Plants
Chemical manufacturing facilities may require lighting equipment suitable for classified industrial locations and corrosive environments.
Food and Beverage Facilities
Certain processing and production environments may require hazardous-location lighting because of combustible dust or other classified operating conditions.
Power Plants
Power generation facilities can benefit from durable industrial lighting for equipment platforms, maintenance areas, and designated hazardous locations.
Paper Mills
Paper processing facilities may include areas requiring protection against dust, moisture, and vibration.
Shipyards and Marine Facilities
The corrosion-resistant aluminum alloy housing and marine-related certification reference make the series relevant to compatible shipyard and marine lighting applications.
Pharmaceutical Manufacturing
Pharmaceutical processing facilities may include designated hazardous locations requiring certified lighting equipment.
Coal Processing Facilities
Coal handling and processing operations may involve combustible dust environments requiring appropriately classified equipment.
For additional facility lighting solutions, explore our industrial lighting fixtures for manufacturing, processing, and infrastructure applications.
Seven Mounting Accessory Configurations
The manufacturer illustrates seven mounting accessory options for the CES-EX-GB-02 Series.
U-Bracket Mounting
Provides an adjustable bracket arrangement for mounting the fixture to suitable structural supports.
Compact U-Bracket Mounting
An alternative bracket arrangement supports installations where a different mounting geometry is required.
Pendant Mounting
Allows the luminaire to be suspended from a compatible overhead conduit or mounting assembly.
90° Wall Mounting
Supports installation on vertical structural surfaces.
25° Stanchion Mounting
Provides an angled mounting arrangement for suitable industrial stanchions.
Ceiling Mounting
Allows direct overhead installation.
Conduit Pole Mounting
Supports installation on compatible conduit-style pole mounting structures.
The manufacturer’s installation drawings also illustrate ceiling, suspension-chain, pendant, wall, and pole installations.
Fixture Dimensions and Weight
| Specification | 30W / 40W | 60W / 80W |
|---|---|---|
| Fixture Diameter | 200 mm (7.87 in.) | 300 mm (11.81 in.) |
| Fixture Height | 157 mm (6.18 in.) | 204 mm (8.03 in.) |
| Net Weight | 3.0 kg (6.61 lb) | 7.0 kg (15.43 lb) |
| Gross Weight | 4.5 kg (9.92 lb) | 8.5 kg (18.74 lb) |
| Carton Quantity | 1 | 1 |
The smaller 30W and 40W configurations provide a compact alternative for installations with limited mounting space.
Technical Specifications
| Specification | CES-EX-GB-02 Series |
|---|---|
| Product Type | Hazardous-Location LED High Bay |
| Models | CES-EX-GB-02-30 / 40 / 60 / 80 |
| Wattages | 30W / 40W / 60W / 80W |
| LED Chips | Bridgelux 3030 |
| Stated Efficacy | 140 lm/W |
| Input Voltage | 100–277V AC |
| Frequency | 50/60Hz |
| Standard Color Temperature | 5000K |
| Additional Color Temperatures | 3000K–6500K |
| CRI | Greater Than 70 |
| Beam Angle | 120° |
| LED Driver | Meanwell |
| Power Factor | Greater Than 0.95 |
| THD | Less Than 10% |
| Surge Protection | 4kV / 6kV Design |
| Rated Life | L70, 50,000 Hours |
| Operating Temperature | −40°C to +50°C |
| Housing | ADC12 Aluminum Alloy |
| Lens | Tempered Glass, 8–10 mm |
| Lens Transmission | Greater Than 90% |
| Class I | Division 2, Groups A–D |
| Class II | Division 2, Groups F–G |
| Class III | Listed |
| Hazardous-Location Standard | UL 844 |
| Additional Listings | UL 1598 / UL 1598A |
| ATEX | Listed Markings and Certificates |
| IECEx | IECEx UL 22.0091X |
| Entry Options | 3/4″-14 NPT / M25 × 1.5 / M26 × 1.5 |
| Standard Cable | 0.5 m STOW, 3 × 18 AWG |
| Mounting | Seven Accessory Configurations |
| Warranty | 5 Years |
Buyer Questions
Which model is best for smaller hazardous-location work areas?
The 30W and 40W models offer the most compact housing and lower power consumption.
Are higher-output models available?
Yes. The series also includes 60W and 80W configurations.
Is the fixture suitable for Class I Division 2 locations?
Yes. The manufacturer identifies Class I Division 2, Groups A, B, C, and D.
Does the series support combustible-dust locations?
Yes. Class II Division 2, Groups F and G, and Class III classifications are listed.
Are ATEX and IECEx certifications available?
The manufacturer provides ATEX and IECEx markings and certificate references.
What mounting options are offered?
U-bracket, compact U-bracket, pendant, wall, stanchion, ceiling, and conduit pole mounting accessories are illustrated.
Is the fixture suitable for marine environments?
The manufacturer identifies corrosion-resistant construction and a UL 1598A marine-related listing.
What is the maximum operating temperature?
The manufacturer specifies an ambient operating range of −40°C to +50°C.
Specify CES-EX-GB-02 Hazardous-Location LED High Bays
The CES-EX-GB-02 Series provides compact, efficient LED illumination for Class I Division 2, Class II Division 2, and Class III industrial environments.
With four wattages from 30W to 80W, Bridgelux LEDs, Meanwell drivers, corrosion-resistant aluminum construction, and multiple mounting configurations, the series supports a wide range of industrial lighting installations.
LED PROS WorldWide provides commercial project quotations and technical product assistance for contractors, engineers, industrial facility managers, and purchasing departments.
Request a CES-EX-GB-02 Project Quote or call 1-844-533-7767.
Provide the required hazardous-location classification, wattage, mounting configuration, voltage, fixture quantity, and project requirements.
Frequently Asked Questions
What is the CES-EX-GB-02 Series?
It is a compact hazardous-location LED high bay series available in 30W, 40W, 60W, and 80W configurations.
Is it rated for Class I Division 2?
Yes. The manufacturer lists Class I Division 2, Groups A, B, C, and D.
Does it support Class II Division 2?
Yes. Groups F and G are identified, along with Class III.
What LED chips are used?
Bridgelux 3030 LEDs.
What driver is included?
The manufacturer specifies a Meanwell LED driver.
What voltage does the fixture require?
100–277V AC, 50/60Hz.
What color temperatures are available?
5000K is standard, with additional options from 3000K to 6500K.
What beam angle is provided?
120°.
What is the operating temperature range?
−40°C to +50°C.
Is the housing corrosion resistant?
The manufacturer specifies corrosion-resistant ADC12 aluminum alloy construction.
What is the rated lifespan?
50,000 hours at L70.
What warranty is included?
Five years.
Stay Connected with Our Lighting Resources
Add IndustrialLightingFixtures.org as a Preferred Source on Google to see more of our lighting guides and technical resources across Google Search experiences.
Related Resources
Class I Division 2 LED Lighting — Explore hazardous-location LED fixtures designed for industrial environments involving flammable gases, vapors, and classified operating conditions.
LED Explosion-Proof Lighting — Compare explosion-proof LED lighting solutions for refineries, chemical processing plants, manufacturing facilities, and industrial infrastructure.
Industrial Lighting — Browse industrial LED lighting fixtures for factories, processing operations, warehouses, and specialized industrial environments.