GYZD81 explosion-proof aircraft obstruction warning lights with low-, medium- and high-intensity configurations for hazardous industrial structures

From $250

Request an Explosion-Proof Obstruction Lighting Quote

Specifying aviation obstruction warning lights for an oil refinery, offshore platform, petrochemical facility, industrial tower, or other structure located within a hazardous area?

Request a Quote or call 1-844-533-7767 for commercial pricing, availability, and technical assistance.

Include your hazardous-area classification, structure height, required light intensity, voltage, fixture quantity, and applicable aviation marking requirements.

Explore our LED aircraft warning lights and obstruction lighting systems for additional aviation safety lighting solutions.

The GYZD81 Series Explosion-Proof Aircraft Obstruction Lights provide red aviation warning illumination for tall industrial structures and installations located within classified hazardous environments. Available in low-, medium-, and high-intensity configurations, the series offers effective luminous intensities exceeding 200, 2,000, and 20,000 candela, respectively. The low- and medium-intensity models use energy-efficient LED technology, while the high-intensity model incorporates a xenon light source.

Designed for demanding industrial applications, the GYZD81 Series is identified for Zone 1 and Zone 2 gas environments and Zone 21 and Zone 22 combustible-dust environments. The fixtures feature IP66 protection, corrosion-resistant metal construction, tempered glass globes, and optional synchronized flashing and solar power configurations. These specialized obstruction lights expand our selection of aircraft warning lights for towers and industrial structures with solutions for hazardous locations where conventional aviation obstruction lights may not provide the required explosion-protection classification.

Explosion-Proof Aviation Obstruction Lighting for Hazardous Areas

The GYZD81 Series combines aviation obstruction warning functionality with hazardous-area equipment protection.

The product family is intended for structures where visible aviation warning signals and appropriate hazardous-location classifications are both important project requirements.

Key Features

  • Low-, medium-, and high-intensity obstruction light configurations.

  • Red warning light output.

  • Effective luminous intensity exceeding 200, 2,000, or 20,000 candela.

  • LED light source on GYZD81-I and GYZD81-II.

  • Xenon light source on GYZD81-III.

  • Zone 1 and Zone 2 gas classification.

  • Zone 21 and Zone 22 dust classification.

  • ATEX explosion-protection marking.

  • IP66 ingress protection.

  • 220V AC, 50Hz input.

  • Optional wireless synchronized flashing.

  • Optional solar panel configuration.

  • Flash rates varying by model.

  • Corrosion-resistant aluminum alloy and stainless steel construction.

  • Epoxy resin powder-coated finish.

  • Tempered glass globe.

  • Silicone rubber gasket.

  • Operating temperature from −40°C to +70°C.

Three Obstruction Light Intensity Configurations

The GYZD81 Series includes three models for different obstruction warning applications.

Specification GYZD81-I GYZD81-II GYZD81-III
Intensity Category Low Medium High
Effective Luminous Intensity Greater than 200 cd Greater than 2,000 cd Greater than 20,000 cd
Light Source LED LED Xenon
Power Consumption 10W 20W 40W
Flash Rate 20–60/min 20–60/min 16–60/min
Weight 2.8 kg 4.8 kg 6.0 kg
Light Color Red Red Red

GYZD81-I — Low-Intensity Explosion-Proof LED Obstruction Light

The GYZD81-I uses a 10W LED light source with an effective luminous intensity greater than 200 candela.

Its compact configuration is intended for applications requiring a lower-intensity red obstruction warning signal.

Key specifications

  • LED light source.

  • Greater than 200 cd.

  • 10W power consumption.

  • 20–60 flashes per minute.

  • 2.8 kg weight.

  • IP66 enclosure protection.

GYZD81-II — Medium-Intensity Explosion-Proof LED Obstruction Light

The GYZD81-II provides greater than 2,000 candela of effective luminous intensity using a 20W LED light source.

This configuration offers a higher-intensity warning signal for projects requiring greater visibility.

Key specifications

  • LED light source.

  • Greater than 2,000 cd.

  • 20W power consumption.

  • 20–60 flashes per minute.

  • 4.8 kg weight.

  • IP66 enclosure protection.

GYZD81-III — High-Intensity Explosion-Proof Obstruction Light

The GYZD81-III provides an effective luminous intensity greater than 20,000 candela.

Unlike the other two models, this configuration uses a xenon lamp rather than LEDs.

Key specifications

  • Xenon light source.

  • Greater than 20,000 cd.

  • 40W power consumption.

  • 16–60 flashes per minute.

  • 6.0 kg weight.

  • IP66 enclosure protection.

Zone 1 and Zone 2 Explosion-Proof Protection

The GYZD81 Series is identified for use in designated hazardous gas environments.

Zone 1 Gas Environments

Zone 1 locations are areas where an explosive gas atmosphere is likely to occur occasionally during normal operation.

Zone 2 Gas Environments

Zone 2 locations are areas where an explosive gas atmosphere is not likely during normal operation, or would normally exist only for a short period.

Gas Explosion-Protection Marking

The published marking is:

II 2G Ex db IIC T6 Gb

This identifies a flameproof enclosure protection method, gas group IIC, temperature class T6, and equipment protection level Gb.

Zone 21 and Zone 22 Combustible-Dust Protection

The GYZD81 Series also includes classifications for designated combustible-dust environments.

Zone 21 Dust Environments

Zone 21 locations may experience an explosive dust atmosphere occasionally during normal operations.

Zone 22 Dust Environments

Zone 22 locations are those where an explosive dust atmosphere is not likely during normal operation, or persists only briefly.

Dust Explosion-Protection Marking

The published marking is:

II 2D Ex tb IIIC T80°C Db IP66

This identifies dust protection by enclosure, dust group IIIC, maximum marked surface temperature of 80°C, and equipment protection level Db.

Red Aviation Warning Light Output

All three GYZD81 models produce red obstruction warning light.

Low-Intensity Red Warning

The GYZD81-I provides greater than 200 cd using LED technology.

Medium-Intensity Red Warning

The GYZD81-II provides greater than 2,000 cd using an LED light source.

High-Intensity Red Warning

The GYZD81-III provides greater than 20,000 cd using a xenon lamp.

Flashing Operation

The specified flashing rates are:

  • GYZD81-I: 20–60 flashes per minute.

  • GYZD81-II: 20–60 flashes per minute.

  • GYZD81-III: 16–60 flashes per minute.

The appropriate obstruction lighting configuration depends on the structure, applicable aviation requirements, and project specifications.

Optional Synchronized Flashing

The GYZD81 Series offers optional wireless synchronized flashing.

This feature is relevant to installations using multiple obstruction warning lights where coordinated flashing is required.

Multiple-Light Installations

Synchronization can support obstruction lighting arrangements involving several warning lights on the same structure or installation.

Wired Synchronization

The product documentation also includes a wired synchronization connection diagram.

The drawing illustrates three lights connected through a common power supply and synchronization wiring arrangement.

Industrial Tower Applications

Synchronized flashing options can be considered for industrial towers, offshore structures, and other installations requiring multiple obstruction lights.

Optional Solar-Powered Configuration

The GYZD81 Series lists an optional solar panel configuration.

This provides a potential alternative for applications where a solar-powered obstruction lighting arrangement is preferred.

The published sheet does not provide solar panel wattage, battery capacity, charging time, or autonomous operating duration.

These details must be established for the specific solar configuration.

220V AC Electrical Operation

The standard published electrical specification is:

220V AC, 50Hz

Power consumption varies by model.

Model Input Voltage Power Consumption
GYZD81-I 220V AC, 50Hz 10W
GYZD81-II 220V AC, 50Hz 20W
GYZD81-III 220V AC, 50Hz 40W

For projects using other electrical supply voltages, the required input configuration should be identified during quotation.

Corrosion-Resistant Industrial Construction

The GYZD81 Series uses durable materials for hazardous industrial and outdoor environments.

Die-Cast Aluminum and Stainless Steel Housing

The product specification identifies die-cast aluminum and stainless steel housing materials.

Epoxy Resin Powder Coating

An epoxy resin powder-coated finish provides additional corrosion resistance.

Stainless Steel Exterior Components

Stainless steel is identified among the exterior materials.

Tempered Glass Globe

The protective globe uses tempered glass.

Silicone Rubber Gasket

A silicone rubber gasket provides enclosure sealing.

IP66 Protection

The IP66 rating indicates dust-tight construction and protection against powerful water jets.

These characteristics support use in demanding industrial environments where moisture, dust, and corrosion are important considerations.

Operating Temperature Range

The GYZD81 Series is specified for ambient temperatures from:

−40°C to +70°C (−40°F to +158°F)

This broad operating range supports applications in cold climates and elevated-temperature industrial environments within the published limits.

Industrial and Aviation Applications

Oil Refineries

Refinery towers, processing structures, and other elevated installations may require obstruction warning lights with hazardous gas classifications.

Petrochemical Plants

Petrochemical facilities may require explosion-proof aviation warning lights on designated towers, vessels, and elevated structures.

Offshore Oil and Gas Platforms

Offshore installations may require obstruction warning lights with corrosion-resistant construction and appropriate hazardous-area protection.

Onshore Oil and Gas Facilities

Elevated structures at onshore oil and gas operations may require specialized aviation warning equipment.

Oil Loading Jetties

Marine loading facilities may require warning lights suited to wet, corrosive, and potentially hazardous operating environments.

Chemical Processing Facilities

Chemical plants may require explosion-proof obstruction lighting on elevated equipment and structures located within classified areas.

Industrial Towers

The GYZD81 Series provides red obstruction warning options for tall industrial structures requiring compatible hazardous-area equipment.

Tall Buildings

The product literature also identifies tall buildings among its potential applications, subject to the applicable aviation marking and electrical requirements.

Military and Specialized Infrastructure

The series may be considered for specialized infrastructure where hazardous-area classifications and aviation obstruction warning requirements intersect.

For other facility illumination requirements, explore our industrial lighting fixtures for manufacturing, processing, and specialized industrial applications.

Mounting and Installation

The GYZD81 Series uses an industrial mounting base intended for secure installation on compatible structures.

GYZD81-I Mounting Dimensions

The published dimensional drawing identifies:

Dimension Measurement
Overall Height 230 mm
Globe Diameter 120 mm
Base Width 170 mm
Mounting Foot Width 140 mm
Mounting Hole Spacing 105 × 105 mm
Mounting Holes Four, 12 mm diameter

These dimensions apply to the GYZD81-I model.

Multi-Light Mounting Arrangements

The installation drawings illustrate obstruction lights installed on horizontal support brackets attached to a vertical structure.

Wired Synchronization Connections

The connection diagram illustrates multiple lights connected using line, neutral, protective earth, and synchronization wiring.

Installation should follow the specified hazardous-area requirements, electrical design, and mounting arrangement for the selected model.

Technical Specifications

Specification GYZD81 Series
Product Type Explosion-Proof Aircraft Obstruction Warning Light
Series GYZD81
Models GYZD81-I / GYZD81-II / GYZD81-III
Warning Light Color Red
Intensity Categories Low / Medium / High
Low-Intensity Output Greater Than 200 cd
Medium-Intensity Output Greater Than 2,000 cd
High-Intensity Output Greater Than 20,000 cd
Low-Intensity Light Source LED
Medium-Intensity Light Source LED
High-Intensity Light Source Xenon
Power Consumption 10W / 20W / 40W
Input Voltage 220V AC
Frequency 50Hz
Flash Rate — Models I and II 20–60 Flashes/Minute
Flash Rate — Model III 16–60 Flashes/Minute
Gas Classification Zone 1 / Zone 2
Dust Classification Zone 21 / Zone 22
Gas Ex Marking II 2G Ex db IIC T6 Gb
Dust Ex Marking II 2D Ex tb IIIC T80°C Db IP66
Ingress Protection IP66
Operating Temperature −40°C to +70°C
Housing Die-Cast Aluminum / Stainless Steel
Exterior Components Stainless Steel
Protective Globe Tempered Glass
Gasket Silicone Rubber
Surface Finish Epoxy Resin Powder Coating
Synchronized Flashing Optional Wireless
Wired Synchronization Connection Diagram Provided
Solar Panel Optional
Listed Certifications / Markings ATEX / CNEX / CE / RoHS
Quality Management ISO 9001
GYZD81-I Weight 2.8 kg
GYZD81-II Weight 4.8 kg
GYZD81-III Weight 6.0 kg
GYZD81-I Overall Height 230 mm
GYZD81-I Base Width 170 mm
GYZD81-I Mounting Pattern 105 × 105 mm

Buyer Questions

Which GYZD81 models use LED technology?

The GYZD81-I and GYZD81-II use LEDs. The GYZD81-III uses a xenon lamp.

What is the difference between the three models?

The primary differences are effective luminous intensity, power consumption, light source, flash rate, and fixture weight.

Are these obstruction lights suitable for Zone 1?

The series is identified for Zone 1 and Zone 2 hazardous gas environments.

Are combustible-dust classifications included?

Yes. Zone 21 and Zone 22 classifications are listed.

Can multiple lights flash together?

Optional wireless synchronized flashing is available, and the product documentation includes a wired synchronization diagram.

Is a solar-powered option available?

A solar panel option is identified in the specification.

What voltage is specified?

220V AC, 50Hz.

What is the operating temperature range?

−40°C to +70°C.

Are these lights FAA approved?

The supplied specification does not document FAA approval or an FAA obstruction-light type designation. Aviation compliance must be established for the selected configuration and project.

Specify Explosion-Proof Obstruction Lights for Your Industrial Structure

The GYZD81 Series provides low-, medium-, and high-intensity red obstruction warning lights for elevated structures located within hazardous industrial environments.

With Zone 1 and Zone 2 gas classifications, Zone 21 and Zone 22 dust classifications, IP66 protection, and optional synchronized flashing, the series offers specialized obstruction lighting configurations for refineries, petrochemical facilities, offshore platforms, and industrial towers.

LED PROS WorldWide provides commercial project quotations and technical product assistance for industrial contractors, engineers, facility managers, and aviation lighting project teams.

Request a GYZD81 Obstruction Lighting Quote or call 1-844-533-7767.

Include the structure height, location, hazardous-area classification, required aviation marking standard, voltage, quantity, and synchronization requirements.

Frequently Asked Questions

What is the GYZD81 Series?

The GYZD81 Series is a family of explosion-proof red aircraft obstruction warning lights for hazardous industrial environments.

How many models are available?

Three: GYZD81-I, GYZD81-II, and GYZD81-III.

What intensity levels are available?

Greater than 200, 2,000, and 20,000 candela.

Are all GYZD81 models LED?

No. The GYZD81-I and GYZD81-II use LEDs. The GYZD81-III uses a xenon lamp.

Are these lights suitable for Zone 1 hazardous locations?

Yes. Zone 1 and Zone 2 gas classifications are identified.

Can they be used in combustible-dust environments?

The series is identified for Zone 21 and Zone 22 dust environments.

What is the ingress protection rating?

IP66.

What is the standard input voltage?

220V AC, 50Hz.

Is synchronized flashing available?

Yes. Optional wireless synchronization is identified, and a wired synchronization diagram is provided.

Is solar power available?

An optional solar panel configuration is listed.

What color are the obstruction lights?

Red.

What is the operating temperature range?

−40°C to +70°C.

Does the product documentation identify FAA approval?

No FAA approval or FAA type designation is provided in the supplied specification.

Stay Connected with Our Lighting Resources

Add IndustrialLightingFixtures.org as a Preferred Source on Google to see more of our lighting guides and technical resources across Google Search experiences.

Related Resources

LED Aircraft Warning Lights — Explore aviation obstruction warning lights for towers, industrial structures, buildings, and specialized infrastructure.

LED Explosion-Proof Lighting — Compare hazardous-location LED lighting solutions for refineries, petrochemical plants, offshore installations, and industrial facilities.

Industrial Lighting — Browse commercial and industrial lighting fixtures for manufacturing facilities, processing plants, and industrial infrastructure.

0/5 (0 Reviews)

Write a Product Review

Your email address will not be published. Reviews are manually approved before publication. Please submit a review based on your actual experience.

This site uses Akismet to reduce spam. Learn how your comment data is processed.