From $250
Request an Explosion-Proof Obstruction Lighting Quote
Specifying aviation obstruction warning lights for an oil refinery, offshore platform, petrochemical facility, industrial tower, or other structure located within a hazardous area?
Request a Quote or call 1-844-533-7767 for commercial pricing, availability, and technical assistance.
Include your hazardous-area classification, structure height, required light intensity, voltage, fixture quantity, and applicable aviation marking requirements.
Explore our LED aircraft warning lights and obstruction lighting systems for additional aviation safety lighting solutions.
The GYZD81 Series Explosion-Proof Aircraft Obstruction Lights provide red aviation warning illumination for tall industrial structures and installations located within classified hazardous environments. Available in low-, medium-, and high-intensity configurations, the series offers effective luminous intensities exceeding 200, 2,000, and 20,000 candela, respectively. The low- and medium-intensity models use energy-efficient LED technology, while the high-intensity model incorporates a xenon light source.
Designed for demanding industrial applications, the GYZD81 Series is identified for Zone 1 and Zone 2 gas environments and Zone 21 and Zone 22 combustible-dust environments. The fixtures feature IP66 protection, corrosion-resistant metal construction, tempered glass globes, and optional synchronized flashing and solar power configurations. These specialized obstruction lights expand our selection of aircraft warning lights for towers and industrial structures with solutions for hazardous locations where conventional aviation obstruction lights may not provide the required explosion-protection classification.
Explosion-Proof Aviation Obstruction Lighting for Hazardous Areas
The GYZD81 Series combines aviation obstruction warning functionality with hazardous-area equipment protection.
The product family is intended for structures where visible aviation warning signals and appropriate hazardous-location classifications are both important project requirements.
Key Features
-
Low-, medium-, and high-intensity obstruction light configurations.
-
Red warning light output.
-
Effective luminous intensity exceeding 200, 2,000, or 20,000 candela.
-
LED light source on GYZD81-I and GYZD81-II.
-
Xenon light source on GYZD81-III.
-
Zone 1 and Zone 2 gas classification.
-
Zone 21 and Zone 22 dust classification.
-
ATEX explosion-protection marking.
-
IP66 ingress protection.
-
220V AC, 50Hz input.
-
Optional wireless synchronized flashing.
-
Optional solar panel configuration.
-
Flash rates varying by model.
-
Corrosion-resistant aluminum alloy and stainless steel construction.
-
Epoxy resin powder-coated finish.
-
Tempered glass globe.
-
Silicone rubber gasket.
-
Operating temperature from −40°C to +70°C.
Three Obstruction Light Intensity Configurations
The GYZD81 Series includes three models for different obstruction warning applications.
| Specification | GYZD81-I | GYZD81-II | GYZD81-III |
|---|---|---|---|
| Intensity Category | Low | Medium | High |
| Effective Luminous Intensity | Greater than 200 cd | Greater than 2,000 cd | Greater than 20,000 cd |
| Light Source | LED | LED | Xenon |
| Power Consumption | 10W | 20W | 40W |
| Flash Rate | 20–60/min | 20–60/min | 16–60/min |
| Weight | 2.8 kg | 4.8 kg | 6.0 kg |
| Light Color | Red | Red | Red |
GYZD81-I — Low-Intensity Explosion-Proof LED Obstruction Light
The GYZD81-I uses a 10W LED light source with an effective luminous intensity greater than 200 candela.
Its compact configuration is intended for applications requiring a lower-intensity red obstruction warning signal.
Key specifications
-
LED light source.
-
Greater than 200 cd.
-
10W power consumption.
-
20–60 flashes per minute.
-
2.8 kg weight.
-
IP66 enclosure protection.
GYZD81-II — Medium-Intensity Explosion-Proof LED Obstruction Light
The GYZD81-II provides greater than 2,000 candela of effective luminous intensity using a 20W LED light source.
This configuration offers a higher-intensity warning signal for projects requiring greater visibility.
Key specifications
-
LED light source.
-
Greater than 2,000 cd.
-
20W power consumption.
-
20–60 flashes per minute.
-
4.8 kg weight.
-
IP66 enclosure protection.
GYZD81-III — High-Intensity Explosion-Proof Obstruction Light
The GYZD81-III provides an effective luminous intensity greater than 20,000 candela.
Unlike the other two models, this configuration uses a xenon lamp rather than LEDs.
Key specifications
-
Xenon light source.
-
Greater than 20,000 cd.
-
40W power consumption.
-
16–60 flashes per minute.
-
6.0 kg weight.
-
IP66 enclosure protection.
Zone 1 and Zone 2 Explosion-Proof Protection
The GYZD81 Series is identified for use in designated hazardous gas environments.
Zone 1 Gas Environments
Zone 1 locations are areas where an explosive gas atmosphere is likely to occur occasionally during normal operation.
Zone 2 Gas Environments
Zone 2 locations are areas where an explosive gas atmosphere is not likely during normal operation, or would normally exist only for a short period.
Gas Explosion-Protection Marking
The published marking is:
II 2G Ex db IIC T6 Gb
This identifies a flameproof enclosure protection method, gas group IIC, temperature class T6, and equipment protection level Gb.
Zone 21 and Zone 22 Combustible-Dust Protection
The GYZD81 Series also includes classifications for designated combustible-dust environments.
Zone 21 Dust Environments
Zone 21 locations may experience an explosive dust atmosphere occasionally during normal operations.
Zone 22 Dust Environments
Zone 22 locations are those where an explosive dust atmosphere is not likely during normal operation, or persists only briefly.
Dust Explosion-Protection Marking
The published marking is:
II 2D Ex tb IIIC T80°C Db IP66
This identifies dust protection by enclosure, dust group IIIC, maximum marked surface temperature of 80°C, and equipment protection level Db.
Red Aviation Warning Light Output
All three GYZD81 models produce red obstruction warning light.
Low-Intensity Red Warning
The GYZD81-I provides greater than 200 cd using LED technology.
Medium-Intensity Red Warning
The GYZD81-II provides greater than 2,000 cd using an LED light source.
High-Intensity Red Warning
The GYZD81-III provides greater than 20,000 cd using a xenon lamp.
Flashing Operation
The specified flashing rates are:
-
GYZD81-I: 20–60 flashes per minute.
-
GYZD81-II: 20–60 flashes per minute.
-
GYZD81-III: 16–60 flashes per minute.
The appropriate obstruction lighting configuration depends on the structure, applicable aviation requirements, and project specifications.
Optional Synchronized Flashing
The GYZD81 Series offers optional wireless synchronized flashing.
This feature is relevant to installations using multiple obstruction warning lights where coordinated flashing is required.
Multiple-Light Installations
Synchronization can support obstruction lighting arrangements involving several warning lights on the same structure or installation.
Wired Synchronization
The product documentation also includes a wired synchronization connection diagram.
The drawing illustrates three lights connected through a common power supply and synchronization wiring arrangement.
Industrial Tower Applications
Synchronized flashing options can be considered for industrial towers, offshore structures, and other installations requiring multiple obstruction lights.
Optional Solar-Powered Configuration
The GYZD81 Series lists an optional solar panel configuration.
This provides a potential alternative for applications where a solar-powered obstruction lighting arrangement is preferred.
The published sheet does not provide solar panel wattage, battery capacity, charging time, or autonomous operating duration.
These details must be established for the specific solar configuration.
220V AC Electrical Operation
The standard published electrical specification is:
220V AC, 50Hz
Power consumption varies by model.
| Model | Input Voltage | Power Consumption |
|---|---|---|
| GYZD81-I | 220V AC, 50Hz | 10W |
| GYZD81-II | 220V AC, 50Hz | 20W |
| GYZD81-III | 220V AC, 50Hz | 40W |
For projects using other electrical supply voltages, the required input configuration should be identified during quotation.
Corrosion-Resistant Industrial Construction
The GYZD81 Series uses durable materials for hazardous industrial and outdoor environments.
Die-Cast Aluminum and Stainless Steel Housing
The product specification identifies die-cast aluminum and stainless steel housing materials.
Epoxy Resin Powder Coating
An epoxy resin powder-coated finish provides additional corrosion resistance.
Stainless Steel Exterior Components
Stainless steel is identified among the exterior materials.
Tempered Glass Globe
The protective globe uses tempered glass.
Silicone Rubber Gasket
A silicone rubber gasket provides enclosure sealing.
IP66 Protection
The IP66 rating indicates dust-tight construction and protection against powerful water jets.
These characteristics support use in demanding industrial environments where moisture, dust, and corrosion are important considerations.
Operating Temperature Range
The GYZD81 Series is specified for ambient temperatures from:
−40°C to +70°C (−40°F to +158°F)
This broad operating range supports applications in cold climates and elevated-temperature industrial environments within the published limits.
Industrial and Aviation Applications
Oil Refineries
Refinery towers, processing structures, and other elevated installations may require obstruction warning lights with hazardous gas classifications.
Petrochemical Plants
Petrochemical facilities may require explosion-proof aviation warning lights on designated towers, vessels, and elevated structures.
Offshore Oil and Gas Platforms
Offshore installations may require obstruction warning lights with corrosion-resistant construction and appropriate hazardous-area protection.
Onshore Oil and Gas Facilities
Elevated structures at onshore oil and gas operations may require specialized aviation warning equipment.
Oil Loading Jetties
Marine loading facilities may require warning lights suited to wet, corrosive, and potentially hazardous operating environments.
Chemical Processing Facilities
Chemical plants may require explosion-proof obstruction lighting on elevated equipment and structures located within classified areas.
Industrial Towers
The GYZD81 Series provides red obstruction warning options for tall industrial structures requiring compatible hazardous-area equipment.
Tall Buildings
The product literature also identifies tall buildings among its potential applications, subject to the applicable aviation marking and electrical requirements.
Military and Specialized Infrastructure
The series may be considered for specialized infrastructure where hazardous-area classifications and aviation obstruction warning requirements intersect.
For other facility illumination requirements, explore our industrial lighting fixtures for manufacturing, processing, and specialized industrial applications.
Mounting and Installation
The GYZD81 Series uses an industrial mounting base intended for secure installation on compatible structures.
GYZD81-I Mounting Dimensions
The published dimensional drawing identifies:
| Dimension | Measurement |
|---|---|
| Overall Height | 230 mm |
| Globe Diameter | 120 mm |
| Base Width | 170 mm |
| Mounting Foot Width | 140 mm |
| Mounting Hole Spacing | 105 × 105 mm |
| Mounting Holes | Four, 12 mm diameter |
These dimensions apply to the GYZD81-I model.
Multi-Light Mounting Arrangements
The installation drawings illustrate obstruction lights installed on horizontal support brackets attached to a vertical structure.
Wired Synchronization Connections
The connection diagram illustrates multiple lights connected using line, neutral, protective earth, and synchronization wiring.
Installation should follow the specified hazardous-area requirements, electrical design, and mounting arrangement for the selected model.
Technical Specifications
| Specification | GYZD81 Series |
|---|---|
| Product Type | Explosion-Proof Aircraft Obstruction Warning Light |
| Series | GYZD81 |
| Models | GYZD81-I / GYZD81-II / GYZD81-III |
| Warning Light Color | Red |
| Intensity Categories | Low / Medium / High |
| Low-Intensity Output | Greater Than 200 cd |
| Medium-Intensity Output | Greater Than 2,000 cd |
| High-Intensity Output | Greater Than 20,000 cd |
| Low-Intensity Light Source | LED |
| Medium-Intensity Light Source | LED |
| High-Intensity Light Source | Xenon |
| Power Consumption | 10W / 20W / 40W |
| Input Voltage | 220V AC |
| Frequency | 50Hz |
| Flash Rate — Models I and II | 20–60 Flashes/Minute |
| Flash Rate — Model III | 16–60 Flashes/Minute |
| Gas Classification | Zone 1 / Zone 2 |
| Dust Classification | Zone 21 / Zone 22 |
| Gas Ex Marking | II 2G Ex db IIC T6 Gb |
| Dust Ex Marking | II 2D Ex tb IIIC T80°C Db IP66 |
| Ingress Protection | IP66 |
| Operating Temperature | −40°C to +70°C |
| Housing | Die-Cast Aluminum / Stainless Steel |
| Exterior Components | Stainless Steel |
| Protective Globe | Tempered Glass |
| Gasket | Silicone Rubber |
| Surface Finish | Epoxy Resin Powder Coating |
| Synchronized Flashing | Optional Wireless |
| Wired Synchronization | Connection Diagram Provided |
| Solar Panel | Optional |
| Listed Certifications / Markings | ATEX / CNEX / CE / RoHS |
| Quality Management | ISO 9001 |
| GYZD81-I Weight | 2.8 kg |
| GYZD81-II Weight | 4.8 kg |
| GYZD81-III Weight | 6.0 kg |
| GYZD81-I Overall Height | 230 mm |
| GYZD81-I Base Width | 170 mm |
| GYZD81-I Mounting Pattern | 105 × 105 mm |
Buyer Questions
Which GYZD81 models use LED technology?
The GYZD81-I and GYZD81-II use LEDs. The GYZD81-III uses a xenon lamp.
What is the difference between the three models?
The primary differences are effective luminous intensity, power consumption, light source, flash rate, and fixture weight.
Are these obstruction lights suitable for Zone 1?
The series is identified for Zone 1 and Zone 2 hazardous gas environments.
Are combustible-dust classifications included?
Yes. Zone 21 and Zone 22 classifications are listed.
Can multiple lights flash together?
Optional wireless synchronized flashing is available, and the product documentation includes a wired synchronization diagram.
Is a solar-powered option available?
A solar panel option is identified in the specification.
What voltage is specified?
220V AC, 50Hz.
What is the operating temperature range?
−40°C to +70°C.
Are these lights FAA approved?
The supplied specification does not document FAA approval or an FAA obstruction-light type designation. Aviation compliance must be established for the selected configuration and project.
Specify Explosion-Proof Obstruction Lights for Your Industrial Structure
The GYZD81 Series provides low-, medium-, and high-intensity red obstruction warning lights for elevated structures located within hazardous industrial environments.
With Zone 1 and Zone 2 gas classifications, Zone 21 and Zone 22 dust classifications, IP66 protection, and optional synchronized flashing, the series offers specialized obstruction lighting configurations for refineries, petrochemical facilities, offshore platforms, and industrial towers.
LED PROS WorldWide provides commercial project quotations and technical product assistance for industrial contractors, engineers, facility managers, and aviation lighting project teams.
Request a GYZD81 Obstruction Lighting Quote or call 1-844-533-7767.
Include the structure height, location, hazardous-area classification, required aviation marking standard, voltage, quantity, and synchronization requirements.
Frequently Asked Questions
What is the GYZD81 Series?
The GYZD81 Series is a family of explosion-proof red aircraft obstruction warning lights for hazardous industrial environments.
How many models are available?
Three: GYZD81-I, GYZD81-II, and GYZD81-III.
What intensity levels are available?
Greater than 200, 2,000, and 20,000 candela.
Are all GYZD81 models LED?
No. The GYZD81-I and GYZD81-II use LEDs. The GYZD81-III uses a xenon lamp.
Are these lights suitable for Zone 1 hazardous locations?
Yes. Zone 1 and Zone 2 gas classifications are identified.
Can they be used in combustible-dust environments?
The series is identified for Zone 21 and Zone 22 dust environments.
What is the ingress protection rating?
IP66.
What is the standard input voltage?
220V AC, 50Hz.
Is synchronized flashing available?
Yes. Optional wireless synchronization is identified, and a wired synchronization diagram is provided.
Is solar power available?
An optional solar panel configuration is listed.
What color are the obstruction lights?
Red.
What is the operating temperature range?
−40°C to +70°C.
Does the product documentation identify FAA approval?
No FAA approval or FAA type designation is provided in the supplied specification.
Stay Connected with Our Lighting Resources
Add IndustrialLightingFixtures.org as a Preferred Source on Google to see more of our lighting guides and technical resources across Google Search experiences.
Related Resources
LED Aircraft Warning Lights — Explore aviation obstruction warning lights for towers, industrial structures, buildings, and specialized infrastructure.
LED Explosion-Proof Lighting — Compare hazardous-location LED lighting solutions for refineries, petrochemical plants, offshore installations, and industrial facilities.
Industrial Lighting — Browse commercial and industrial lighting fixtures for manufacturing facilities, processing plants, and industrial infrastructure.