ES03 explosion-proof LED exit signs and emergency lights for Class I Division 1 and Division 2 hazardous locations

From $1700

Request an Explosion-Proof Emergency Lighting Quote

Specifying emergency egress lighting for a refinery, chemical processing plant, wastewater treatment facility, power plant, or classified industrial environment?

Request a Quote or call 1-844-533-7767 for commercial pricing, product availability, and technical assistance.

Include your hazardous-location classification, required emergency lighting configuration, voltage, fixture quantity, and project specifications.

Explore our explosion-proof LED exit signs and emergency lighting for additional hazardous-location life-safety equipment.

The ES03 Series Explosion-Proof LED Exit Signs and Emergency Lights provide illuminated exit identification and emergency egress lighting for industrial environments where flammable gases, vapors, or combustible dust may be present. Available in four configurations, the series includes dual-head emergency lights, a combination emergency light and illuminated EXIT sign, and a standalone LED exit sign. The emergency lighting models provide adjustable LED spotlights with a manufacturer-specified three-hour emergency operating duration.

Designed for demanding hazardous-location applications, the ES03 Series offers Class I Division 1, Class I Division 2, Class II Division 1, Class II Division 2, Class III, and Class I Zone 1 classifications. With UL 844 and UL 924 compliance, IP66/NEMA 4X protection, and durable die-cast aluminum construction, these fixtures complement our selection of hazardous-location LED exit signs and emergency lights for industrial facilities requiring dependable emergency egress equipment.

Four Explosion-Proof Emergency Lighting Configurations

The ES03 Series includes four fixture designs for different emergency lighting and exit identification requirements.

ES03A1 — Dual-Head Explosion-Proof LED Emergency Light

The ES03A1 features two adjustable LED emergency spotlights mounted on a rectangular aluminum enclosure.

Its dual-head design provides directional emergency illumination for industrial exits, equipment platforms, access routes, and designated egress pathways.

Features

  • Two adjustable LED emergency spotlights.

  • Three-hour emergency operating duration.

  • 120–277V AC input.

  • Horizontal and vertical spotlight adjustment.

  • 90° or 120° beam angle.

  • Wall mounting.

  • IP66/NEMA 4X protection.

ES03C1 — Compact Explosion-Proof LED Emergency Light

The ES03C1 provides dual-head emergency illumination in a smaller enclosure.

Its compact construction is suitable for industrial locations where mounting space is limited.

Features

  • Compact dual-head emergency light.

  • Three-hour emergency operation.

  • 120–277V AC input.

  • Adjustable spotlight positioning.

  • Screw-secured enclosure cover.

  • Wall mounting.

  • IP66 protection.

ES03A2 — Combination Explosion-Proof LED Exit Sign & Emergency Light

The ES03A2 combines an illuminated EXIT sign with two adjustable emergency spotlights.

This integrated configuration provides both exit identification and directional emergency illumination from one assembly.

Features

  • Illuminated EXIT sign.

  • Two adjustable emergency spotlights.

  • Red or green exit lettering.

  • Three-hour emergency operation.

  • Independent battery backup systems for the sign and spotlights.

  • 120–277V AC input.

  • Tempered glass sign panel.

  • Customizable exit sign markings.

ES03A3 — Explosion-Proof LED Exit Sign

The ES03A3 provides illuminated exit identification without emergency spotlights.

This configuration is designed for hazardous-location applications requiring a standalone LED exit sign.

Features

  • Illuminated EXIT sign.

  • Red or green lettering.

  • Tempered glass sign panel.

  • 100–277V AC or 12–48V DC input options.

  • Wall mounting.

  • IP66/NEMA 4X protection.

ES03 Series Model Comparison

Model Configuration Emergency Spotlights Exit Sign Emergency Duration
ES03A1 Emergency Light Two No 3 Hours
ES03C1 Compact Emergency Light Two No 3 Hours
ES03A2 Combination Exit Sign / Emergency Light Two Yes 3 Hours
ES03A3 Standalone Exit Sign No Yes Not Specified

Class I Division 1 and Division 2 Hazardous-Location Protection

The ES03 Series is designed for classified industrial environments where emergency lighting equipment must meet applicable hazardous-location requirements.

Class I Division 1 — Groups C and D

Suitable for designated locations involving flammable gases or vapors that may be present under normal operating conditions.

Class I Division 2 — Groups A, B, C, and D

The series also supports designated Class I Division 2 environments where flammable gases or vapors are not normally present at hazardous concentrations.

Class II Division 1 — Groups E, F, and G

The series is identified for classified locations involving combustible dust.

Class II Division 2 — Groups F and G

Additional protection is provided for applicable combustible-dust environments.

Class III and Zone 1

The series also includes:

  • Class III hazardous locations.

  • Class I Zone 1, Group IIB.

UL 844 and UL 924 Emergency Lighting Compliance

The ES03 Series is identified with the following standards and protection ratings:

  • UL 844: Hazardous-location luminaires.

  • UL 924: Emergency lighting and power equipment.

  • ETL: Listed certification.

  • NEMA 4X: Environmental enclosure protection.

  • IP66: Dust-tight protection and resistance to powerful water jets.

  • Wet Locations: Suitable for designated wet-location applications.

  • IK10: Enclosure impact resistance.

  • IK08: Protected tempered glass impact resistance with metal guard.

These specifications support the selection of emergency lighting equipment for classified industrial locations.

Three-Hour Emergency Lighting Operation

The ES03A1, ES03C1, and ES03A2 provide a specified three-hour emergency operating duration.

Battery Backup

The emergency lighting models incorporate battery backup systems that support illumination during interruptions to normal electrical power.

Independent Battery Systems

The combination ES03A2 configuration uses independent battery backup systems for the exit sign and emergency spotlights.

Adjustable Emergency Spotlights

The emergency lighting heads can be adjusted horizontally and vertically.

The specified adjustment range is 0° to 180°.

Emergency Beam Distribution

Available spotlight beam angles include:

  • 90°.

  • 120°.

These distributions support emergency illumination across industrial walkways, exits, and designated egress routes.

Electrical Specifications

Emergency Spotlight Power Consumption

Electrical Condition Two-Spotlight Power
120V AC — Fully Charged 7W
120V AC — During Charging 10W
277V AC — Fully Charged 9W
277V AC — During Charging 12W

These values apply to the emergency spotlight assemblies on the ES03A1, ES03C1, and ES03A2.

Illuminated Exit Signs

The ES03A2 and ES03A3 illuminated exit signs have a specified power consumption of 3W–5W.

Input Voltage by Model

Model Input Voltage
ES03A1 120–277V AC
ES03C1 120–277V AC
ES03A2 120–277V AC
ES03A3 100–277V AC / 12–48V DC

AC configurations operate at 50/60Hz.

Red and Green LED Exit Sign Options

The ES03A2 and ES03A3 are available with illuminated exit sign markings.

Red EXIT Signs

Red illuminated lettering provides visible exit identification in industrial environments.

Green EXIT Signs

Green illuminated lettering is available for facilities requiring that color.

Custom Exit Sign Markings

Multiple exit sign label designs are available, including customizable markings.

Tempered Glass Sign Panels

The ES03A2 and ES03A3 use tempered glass panels to protect the illuminated exit sign display.

Durable Industrial Construction

The ES03 Series uses materials selected for demanding hazardous-location environments.

Die-Cast Aluminum Housing

All four models feature die-cast aluminum enclosures.

Stainless Steel Hardware

Stainless steel hardware is used throughout the series.

Tempered Glass Components

The emergency lighting models use tempered glass diffusers, while the exit sign models incorporate tempered glass sign panels.

Protected Enclosure Design

The ES03A1, ES03A2, and ES03A3 feature hinged covers secured with screws.

The compact ES03C1 uses a screw-secured cover plate.

Industrial Applications

Oil Refineries and Petrochemical Facilities

Explosion-proof emergency lights and exit signs provide emergency egress equipment for designated hazardous areas within refining and petrochemical operations.

Chemical Processing Plants

Chemical manufacturing facilities may require classified emergency lighting around processing equipment, production areas, and exit routes.

Wastewater Treatment Plants

Wastewater facilities may contain hazardous gases, moisture, and corrosive conditions requiring specialized emergency lighting equipment.

Power Generation Facilities

Power plants may require emergency illumination around equipment rooms, service platforms, and industrial walkways.

Paper Mills

Paper processing operations may include combustible dust and other industrial conditions requiring appropriately classified equipment.

Metallurgical Facilities

Metal processing facilities may require durable emergency lighting for production areas, equipment platforms, and designated exits.

Food and Beverage Processing

Selected production and processing environments may require hazardous-location emergency lighting where flammable materials or combustible dust are present.

Industrial Storage Facilities

Industrial storage and handling operations may require illuminated exit identification and emergency lighting in classified areas.

For additional facility lighting solutions, explore our industrial lighting fixtures for manufacturing plants, processing facilities, and specialized industrial environments.

Wall-Mounted Installation

All ES03 configurations are designed for wall mounting.

Adjustable Spotlight Positioning

The ES03A1, ES03C1, and ES03A2 provide adjustable emergency lighting heads.

Conduit Connections

The series includes 3/4-inch NPT conduit connections.

Initial Battery Charging

The installation instructions specify an initial battery charging period exceeding 24 hours before first use.

Hazardous-Location Installation

Electrical installation must follow the applicable hazardous-location classification and the requirements for approved conduit, cable entry, and mounting equipment.

Fixture Dimensions and Weight

Model Published Dimensions Net Weight
ES03A1 546 × 430 × 159 mm 20 kg / 44.09 lb
ES03C1 305 × 320.5 × 165.5 mm 8 kg / 17.64 lb
ES03A2 546 × 648 × 159 mm 25 kg / 55.12 lb
ES03A3 546 × 539 × 159 mm 25 kg / 55.12 lb

Technical Specifications

Specification ES03 Series
Product Type Explosion-Proof LED Exit Sign / Emergency Light
Models ES03A1 / ES03C1 / ES03A2 / ES03A3
Emergency Spotlights Two — A1 / C1 / A2
Illuminated Exit Sign A2 / A3
Emergency Duration 3 Hours — A1 / C1 / A2
Spotlight CCT 3000K–6500K
Spotlight Beam Angles 90° / 120°
Spotlight Adjustment 0°–180°
Exit Sign Colors Red / Green
Exit Sign Power 3W–5W
Emergency Light Voltage 120–277V AC
ES03A3 Voltage 100–277V AC / 12–48V DC
Frequency 50/60Hz
Class I Division 1 Groups C, D
Class I Division 2 Groups A, B, C, D
Class II Division 1 Groups E, F, G
Class II Division 2 Groups F, G
Class III Listed
Class I Zone 1 Group IIB
Standards UL 844 / UL 924
Certification ETL
Enclosure Rating NEMA 4X
Ingress Protection IP66
Impact Rating IK10 Enclosure / IK08 Protected Glass
Housing Die-Cast Aluminum
Glass Components Tempered Glass
Hardware Stainless Steel
Mounting Wall
Conduit Entry 3/4-inch NPT
Battery Charging Temperature 0°C to +45°C
Battery Discharging Temperature −20°C to +60°C
Stated LED Lifespan 50,000 Hours
Warranty 5-Year Limited

Buyer Questions

Which model combines an EXIT sign and emergency lighting?

The ES03A2 includes an illuminated EXIT sign and two adjustable emergency spotlights.

Which model is a standalone EXIT sign?

The ES03A3 provides illuminated exit identification without emergency spotlights.

Which model offers the smallest emergency lighting enclosure?

The ES03C1 is the compact dual-head emergency light configuration.

Are these fixtures suitable for Class I Division 1 locations?

The series is identified for Class I Division 1, Groups C and D.

Are Class I Division 2 configurations available?

Yes. Groups A, B, C, and D are listed.

How long does emergency lighting operate?

The ES03A1, ES03C1, and ES03A2 provide three-hour emergency operation.

Are Made-in-USA configurations available?

Yes. The ordering guide identifies an optional U.S.-manufactured configuration.

Can the emergency spotlights be adjusted?

Yes. The spotlight assemblies provide horizontal and vertical adjustment.

Explosion-Proof Exit Signs and Emergency Lighting for Your Facility

The ES03 Series provides multiple emergency lighting and exit identification configurations for hazardous industrial environments.

From compact dual-head emergency lights to combination exit sign assemblies, the product family offers Class I Division 1 and Division 2 protection, three-hour emergency operation on equipped models, and durable IP66/NEMA 4X construction.

LED PROS WorldWide provides commercial project quotations and technical product assistance for electrical contractors, engineers, industrial facility managers, and purchasing departments.

Request an ES03 Project Quote or call 1-844-533-7767.

Include the required model, hazardous-location classification, electrical supply, fixture quantity, and project specifications.

Frequently Asked Questions

What is the ES03 Series?

The ES03 Series includes explosion-proof LED emergency lights, combination emergency light/exit signs, and standalone illuminated exit signs.

What models are available?

ES03A1, ES03C1, ES03A2, and ES03A3.

Which model combines an EXIT sign and emergency spotlights?

The ES03A2.

Which models provide three-hour emergency operation?

The ES03A1, ES03C1, and ES03A2.

Are the fixtures suitable for Class I Division 1 locations?

The series is identified for Class I Division 1, Groups C and D.

Are Class II Division 1 locations supported?

Yes. Groups E, F, and G are listed.

Does the series meet UL 924?

UL 924 emergency lighting compliance is listed.

Are red and green exit signs available?

Yes. Both colors are available.

What is the enclosure protection rating?

IP66 and NEMA 4X.

Is a Made-in-USA configuration available?

Yes. An optional Made-in-USA ordering configuration is identified.

What warranty is provided?

Five-year limited warranty.

Stay Connected with Our Lighting Resources

Add IndustrialLightingFixtures.org as a Preferred Source on Google to see more of our lighting guides and technical resources across Google Search experiences.

Related Resources

Explosion-Proof LED Exit Signs — Explore hazardous-location exit signs and emergency lighting equipment for industrial egress applications.

Class I Division 2 LED Lighting — Compare LED fixtures for classified industrial environments involving flammable gases and vapors.

LED Explosion-Proof Lighting — Browse hazardous-location LED lighting for refineries, chemical processing plants, manufacturing operations, and industrial infrastructure.

Industrial Lighting — Explore commercial and industrial LED lighting fixtures for manufacturing, processing, and specialized industrial facilities.

0/5 (0 Reviews)

Write a Product Review

Your email address will not be published. Reviews are manually approved before publication. Please submit a review based on your actual experience.

This site uses Akismet to reduce spam. Learn how your comment data is processed.