From $1700
Request an Explosion-Proof Emergency Lighting Quote
Specifying emergency egress lighting for a refinery, chemical processing plant, wastewater treatment facility, power plant, or classified industrial environment?
Request a Quote or call 1-844-533-7767 for commercial pricing, product availability, and technical assistance.
Include your hazardous-location classification, required emergency lighting configuration, voltage, fixture quantity, and project specifications.
Explore our explosion-proof LED exit signs and emergency lighting for additional hazardous-location life-safety equipment.
The ES03 Series Explosion-Proof LED Exit Signs and Emergency Lights provide illuminated exit identification and emergency egress lighting for industrial environments where flammable gases, vapors, or combustible dust may be present. Available in four configurations, the series includes dual-head emergency lights, a combination emergency light and illuminated EXIT sign, and a standalone LED exit sign. The emergency lighting models provide adjustable LED spotlights with a manufacturer-specified three-hour emergency operating duration.
Designed for demanding hazardous-location applications, the ES03 Series offers Class I Division 1, Class I Division 2, Class II Division 1, Class II Division 2, Class III, and Class I Zone 1 classifications. With UL 844 and UL 924 compliance, IP66/NEMA 4X protection, and durable die-cast aluminum construction, these fixtures complement our selection of hazardous-location LED exit signs and emergency lights for industrial facilities requiring dependable emergency egress equipment.
Four Explosion-Proof Emergency Lighting Configurations
The ES03 Series includes four fixture designs for different emergency lighting and exit identification requirements.
ES03A1 — Dual-Head Explosion-Proof LED Emergency Light
The ES03A1 features two adjustable LED emergency spotlights mounted on a rectangular aluminum enclosure.
Its dual-head design provides directional emergency illumination for industrial exits, equipment platforms, access routes, and designated egress pathways.
Features
-
Two adjustable LED emergency spotlights.
-
Three-hour emergency operating duration.
-
120–277V AC input.
-
Horizontal and vertical spotlight adjustment.
-
90° or 120° beam angle.
-
Wall mounting.
-
IP66/NEMA 4X protection.
ES03C1 — Compact Explosion-Proof LED Emergency Light
The ES03C1 provides dual-head emergency illumination in a smaller enclosure.
Its compact construction is suitable for industrial locations where mounting space is limited.
Features
-
Compact dual-head emergency light.
-
Three-hour emergency operation.
-
120–277V AC input.
-
Adjustable spotlight positioning.
-
Screw-secured enclosure cover.
-
Wall mounting.
-
IP66 protection.
ES03A2 — Combination Explosion-Proof LED Exit Sign & Emergency Light
The ES03A2 combines an illuminated EXIT sign with two adjustable emergency spotlights.
This integrated configuration provides both exit identification and directional emergency illumination from one assembly.
Features
-
Illuminated EXIT sign.
-
Two adjustable emergency spotlights.
-
Red or green exit lettering.
-
Three-hour emergency operation.
-
Independent battery backup systems for the sign and spotlights.
-
120–277V AC input.
-
Tempered glass sign panel.
-
Customizable exit sign markings.
ES03A3 — Explosion-Proof LED Exit Sign
The ES03A3 provides illuminated exit identification without emergency spotlights.
This configuration is designed for hazardous-location applications requiring a standalone LED exit sign.
Features
-
Illuminated EXIT sign.
-
Red or green lettering.
-
Tempered glass sign panel.
-
100–277V AC or 12–48V DC input options.
-
Wall mounting.
-
IP66/NEMA 4X protection.
ES03 Series Model Comparison
| Model | Configuration | Emergency Spotlights | Exit Sign | Emergency Duration |
|---|---|---|---|---|
| ES03A1 | Emergency Light | Two | No | 3 Hours |
| ES03C1 | Compact Emergency Light | Two | No | 3 Hours |
| ES03A2 | Combination Exit Sign / Emergency Light | Two | Yes | 3 Hours |
| ES03A3 | Standalone Exit Sign | No | Yes | Not Specified |
Class I Division 1 and Division 2 Hazardous-Location Protection
The ES03 Series is designed for classified industrial environments where emergency lighting equipment must meet applicable hazardous-location requirements.
Class I Division 1 — Groups C and D
Suitable for designated locations involving flammable gases or vapors that may be present under normal operating conditions.
Class I Division 2 — Groups A, B, C, and D
The series also supports designated Class I Division 2 environments where flammable gases or vapors are not normally present at hazardous concentrations.
Class II Division 1 — Groups E, F, and G
The series is identified for classified locations involving combustible dust.
Class II Division 2 — Groups F and G
Additional protection is provided for applicable combustible-dust environments.
Class III and Zone 1
The series also includes:
-
Class III hazardous locations.
-
Class I Zone 1, Group IIB.
UL 844 and UL 924 Emergency Lighting Compliance
The ES03 Series is identified with the following standards and protection ratings:
-
UL 844: Hazardous-location luminaires.
-
UL 924: Emergency lighting and power equipment.
-
ETL: Listed certification.
-
NEMA 4X: Environmental enclosure protection.
-
IP66: Dust-tight protection and resistance to powerful water jets.
-
Wet Locations: Suitable for designated wet-location applications.
-
IK10: Enclosure impact resistance.
-
IK08: Protected tempered glass impact resistance with metal guard.
These specifications support the selection of emergency lighting equipment for classified industrial locations.
Three-Hour Emergency Lighting Operation
The ES03A1, ES03C1, and ES03A2 provide a specified three-hour emergency operating duration.
Battery Backup
The emergency lighting models incorporate battery backup systems that support illumination during interruptions to normal electrical power.
Independent Battery Systems
The combination ES03A2 configuration uses independent battery backup systems for the exit sign and emergency spotlights.
Adjustable Emergency Spotlights
The emergency lighting heads can be adjusted horizontally and vertically.
The specified adjustment range is 0° to 180°.
Emergency Beam Distribution
Available spotlight beam angles include:
-
90°.
-
120°.
These distributions support emergency illumination across industrial walkways, exits, and designated egress routes.
Electrical Specifications
Emergency Spotlight Power Consumption
| Electrical Condition | Two-Spotlight Power |
|---|---|
| 120V AC — Fully Charged | 7W |
| 120V AC — During Charging | 10W |
| 277V AC — Fully Charged | 9W |
| 277V AC — During Charging | 12W |
These values apply to the emergency spotlight assemblies on the ES03A1, ES03C1, and ES03A2.
Illuminated Exit Signs
The ES03A2 and ES03A3 illuminated exit signs have a specified power consumption of 3W–5W.
Input Voltage by Model
| Model | Input Voltage |
|---|---|
| ES03A1 | 120–277V AC |
| ES03C1 | 120–277V AC |
| ES03A2 | 120–277V AC |
| ES03A3 | 100–277V AC / 12–48V DC |
AC configurations operate at 50/60Hz.
Red and Green LED Exit Sign Options
The ES03A2 and ES03A3 are available with illuminated exit sign markings.
Red EXIT Signs
Red illuminated lettering provides visible exit identification in industrial environments.
Green EXIT Signs
Green illuminated lettering is available for facilities requiring that color.
Custom Exit Sign Markings
Multiple exit sign label designs are available, including customizable markings.
Tempered Glass Sign Panels
The ES03A2 and ES03A3 use tempered glass panels to protect the illuminated exit sign display.
Durable Industrial Construction
The ES03 Series uses materials selected for demanding hazardous-location environments.
Die-Cast Aluminum Housing
All four models feature die-cast aluminum enclosures.
Stainless Steel Hardware
Stainless steel hardware is used throughout the series.
Tempered Glass Components
The emergency lighting models use tempered glass diffusers, while the exit sign models incorporate tempered glass sign panels.
Protected Enclosure Design
The ES03A1, ES03A2, and ES03A3 feature hinged covers secured with screws.
The compact ES03C1 uses a screw-secured cover plate.
Industrial Applications
Oil Refineries and Petrochemical Facilities
Explosion-proof emergency lights and exit signs provide emergency egress equipment for designated hazardous areas within refining and petrochemical operations.
Chemical Processing Plants
Chemical manufacturing facilities may require classified emergency lighting around processing equipment, production areas, and exit routes.
Wastewater Treatment Plants
Wastewater facilities may contain hazardous gases, moisture, and corrosive conditions requiring specialized emergency lighting equipment.
Power Generation Facilities
Power plants may require emergency illumination around equipment rooms, service platforms, and industrial walkways.
Paper Mills
Paper processing operations may include combustible dust and other industrial conditions requiring appropriately classified equipment.
Metallurgical Facilities
Metal processing facilities may require durable emergency lighting for production areas, equipment platforms, and designated exits.
Food and Beverage Processing
Selected production and processing environments may require hazardous-location emergency lighting where flammable materials or combustible dust are present.
Industrial Storage Facilities
Industrial storage and handling operations may require illuminated exit identification and emergency lighting in classified areas.
For additional facility lighting solutions, explore our industrial lighting fixtures for manufacturing plants, processing facilities, and specialized industrial environments.
Wall-Mounted Installation
All ES03 configurations are designed for wall mounting.
Adjustable Spotlight Positioning
The ES03A1, ES03C1, and ES03A2 provide adjustable emergency lighting heads.
Conduit Connections
The series includes 3/4-inch NPT conduit connections.
Initial Battery Charging
The installation instructions specify an initial battery charging period exceeding 24 hours before first use.
Hazardous-Location Installation
Electrical installation must follow the applicable hazardous-location classification and the requirements for approved conduit, cable entry, and mounting equipment.
Fixture Dimensions and Weight
| Model | Published Dimensions | Net Weight |
|---|---|---|
| ES03A1 | 546 × 430 × 159 mm | 20 kg / 44.09 lb |
| ES03C1 | 305 × 320.5 × 165.5 mm | 8 kg / 17.64 lb |
| ES03A2 | 546 × 648 × 159 mm | 25 kg / 55.12 lb |
| ES03A3 | 546 × 539 × 159 mm | 25 kg / 55.12 lb |
Technical Specifications
| Specification | ES03 Series |
|---|---|
| Product Type | Explosion-Proof LED Exit Sign / Emergency Light |
| Models | ES03A1 / ES03C1 / ES03A2 / ES03A3 |
| Emergency Spotlights | Two — A1 / C1 / A2 |
| Illuminated Exit Sign | A2 / A3 |
| Emergency Duration | 3 Hours — A1 / C1 / A2 |
| Spotlight CCT | 3000K–6500K |
| Spotlight Beam Angles | 90° / 120° |
| Spotlight Adjustment | 0°–180° |
| Exit Sign Colors | Red / Green |
| Exit Sign Power | 3W–5W |
| Emergency Light Voltage | 120–277V AC |
| ES03A3 Voltage | 100–277V AC / 12–48V DC |
| Frequency | 50/60Hz |
| Class I Division 1 | Groups C, D |
| Class I Division 2 | Groups A, B, C, D |
| Class II Division 1 | Groups E, F, G |
| Class II Division 2 | Groups F, G |
| Class III | Listed |
| Class I Zone 1 | Group IIB |
| Standards | UL 844 / UL 924 |
| Certification | ETL |
| Enclosure Rating | NEMA 4X |
| Ingress Protection | IP66 |
| Impact Rating | IK10 Enclosure / IK08 Protected Glass |
| Housing | Die-Cast Aluminum |
| Glass Components | Tempered Glass |
| Hardware | Stainless Steel |
| Mounting | Wall |
| Conduit Entry | 3/4-inch NPT |
| Battery Charging Temperature | 0°C to +45°C |
| Battery Discharging Temperature | −20°C to +60°C |
| Stated LED Lifespan | 50,000 Hours |
| Warranty | 5-Year Limited |
Buyer Questions
Which model combines an EXIT sign and emergency lighting?
The ES03A2 includes an illuminated EXIT sign and two adjustable emergency spotlights.
Which model is a standalone EXIT sign?
The ES03A3 provides illuminated exit identification without emergency spotlights.
Which model offers the smallest emergency lighting enclosure?
The ES03C1 is the compact dual-head emergency light configuration.
Are these fixtures suitable for Class I Division 1 locations?
The series is identified for Class I Division 1, Groups C and D.
Are Class I Division 2 configurations available?
Yes. Groups A, B, C, and D are listed.
How long does emergency lighting operate?
The ES03A1, ES03C1, and ES03A2 provide three-hour emergency operation.
Are Made-in-USA configurations available?
Yes. The ordering guide identifies an optional U.S.-manufactured configuration.
Can the emergency spotlights be adjusted?
Yes. The spotlight assemblies provide horizontal and vertical adjustment.
Explosion-Proof Exit Signs and Emergency Lighting for Your Facility
The ES03 Series provides multiple emergency lighting and exit identification configurations for hazardous industrial environments.
From compact dual-head emergency lights to combination exit sign assemblies, the product family offers Class I Division 1 and Division 2 protection, three-hour emergency operation on equipped models, and durable IP66/NEMA 4X construction.
LED PROS WorldWide provides commercial project quotations and technical product assistance for electrical contractors, engineers, industrial facility managers, and purchasing departments.
Request an ES03 Project Quote or call 1-844-533-7767.
Include the required model, hazardous-location classification, electrical supply, fixture quantity, and project specifications.
Frequently Asked Questions
What is the ES03 Series?
The ES03 Series includes explosion-proof LED emergency lights, combination emergency light/exit signs, and standalone illuminated exit signs.
What models are available?
ES03A1, ES03C1, ES03A2, and ES03A3.
Which model combines an EXIT sign and emergency spotlights?
The ES03A2.
Which models provide three-hour emergency operation?
The ES03A1, ES03C1, and ES03A2.
Are the fixtures suitable for Class I Division 1 locations?
The series is identified for Class I Division 1, Groups C and D.
Are Class II Division 1 locations supported?
Yes. Groups E, F, and G are listed.
Does the series meet UL 924?
UL 924 emergency lighting compliance is listed.
Are red and green exit signs available?
Yes. Both colors are available.
What is the enclosure protection rating?
IP66 and NEMA 4X.
Is a Made-in-USA configuration available?
Yes. An optional Made-in-USA ordering configuration is identified.
What warranty is provided?
Five-year limited warranty.
Stay Connected with Our Lighting Resources
Add IndustrialLightingFixtures.org as a Preferred Source on Google to see more of our lighting guides and technical resources across Google Search experiences.
Related Resources
Explosion-Proof LED Exit Signs — Explore hazardous-location exit signs and emergency lighting equipment for industrial egress applications.
Class I Division 2 LED Lighting — Compare LED fixtures for classified industrial environments involving flammable gases and vapors.
LED Explosion-Proof Lighting — Browse hazardous-location LED lighting for refineries, chemical processing plants, manufacturing operations, and industrial infrastructure.
Industrial Lighting — Explore commercial and industrial LED lighting fixtures for manufacturing, processing, and specialized industrial facilities.