The EX-HTA High-Temperature Explosion-Proof LED Linear Light is engineered for industrial environments where elevated ambient temperatures and hazardous-location conditions demand specialized lighting equipment. Available in 2-foot HTA2 and 4-foot HTA4 configurations, the series delivers 1,300–13,000 lumens with wattages from 10W to 100W. Its driverless integrated-circuit design, aluminum housing, and thermal management construction support operation in ambient temperatures as high as 110°C (230°F) on selected models.
Designed for demanding industrial applications, the EX-HTA Series provides Class I Division 2, Class II Division 2, and Class III hazardous-location protection, along with IP66 ingress protection, NEMA 4X construction, and IK10 impact protection with a wire guard. These fixtures expand our high temperature high bay lighting for facilities requiring both high-temperature performance and hazardous-location compliance.
High-Temperature LED Lighting for Hazardous Locations
The EX-HTA Series combines elevated-temperature operation with hazardous-location construction.
Its compact linear design supports installations around process equipment, industrial production lines, loading platforms, and other locations where conventional LED luminaires may not be suitable.
Key Features
-
Maximum ambient temperature up to 110°C (230°F), model dependent.
-
Two fixture lengths: HTA2 and HTA4.
-
Wattages from 10W to 100W.
-
Lumen output from 1,300 to 13,000 lumens.
-
Rated luminous efficacy of 130 lm/W.
-
Driverless integrated-circuit design.
-
120–277V AC input.
-
Class I Division 2, Groups A, B, C, D.
-
Class II Division 2, Groups F, G.
-
Class III hazardous locations.
-
UL 844 hazardous-location compliance.
-
UL 1598 luminaire compliance.
-
IP66 ingress protection.
-
NEMA 4X enclosure designation.
-
IK10 impact protection with wire guard.
-
3G vibration rating.
-
ABS designation.
-
Die-cast aluminum housing.
-
Frosted glass diffuser.
-
Stainless steel 304 hardware.
-
120° beam angle.
-
Included U-bracket mounting.
-
Optional pole and pendant mounting.
-
Up to 50,000-hour stated service life.
Maximum Ambient Temperature by Wattage
The EX-HTA Series is available in several wattages with different maximum ambient operating temperatures.
Lower-wattage configurations support the highest ambient temperatures, while higher-wattage configurations have lower maximum ambient ratings.
HTA2 — 2-Foot Series
| Model | Wattage | Lumen Output | Ambient Operating Range |
|---|---|---|---|
| HTA2-20W | 20W | 2,600 lm | −40°C to +105°C |
| HTA2-30W | 30W | 3,900 lm | −40°C to +100°C |
| HTA2-40W | 40W | 5,200 lm | −40°C to +95°C |
| HTA2-50W | 50W | 6,500 lm | −40°C to +85°C |
HTA4 — 4-Foot Series
| Model | Wattage | Lumen Output | Ambient Operating Range |
|---|---|---|---|
| HTA4-10W | 10W | 1,300 lm | −40°C to +110°C |
| HTA4-20W | 20W | 2,600 lm | −40°C to +110°C |
| HTA4-30W | 30W | 3,900 lm | −40°C to +105°C |
| HTA4-40W | 40W | 5,200 lm | −40°C to +105°C |
| HTA4-50W | 50W | 6,500 lm | −40°C to +100°C |
| HTA4-60W | 60W | 7,800 lm | −40°C to +95°C |
| HTA4-80W | 80W | 10,400 lm | −40°C to +95°C |
| HTA4-100W | 100W | 13,000 lm | −40°C to +80°C |
Maximum ambient temperature is configuration-specific. The 110°C rating applies to the HTA4 10W and 20W models.
Hazardous-Location Classifications and Compliance
The VENAS EX-HTA Series is designed for classified industrial environments where flammable gases, combustible dust, or other hazardous materials may be present.
Class I, Division 2 — Groups A, B, C, D
Suitable for designated Class I Division 2 locations involving flammable gases or vapors that are not normally present at hazardous concentrations during standard operation.
Class II, Division 2 — Groups F, G
Designed for applicable Class II Division 2 environments involving combustible dust.
Class III
The manufacturer also identifies Class III hazardous-location compliance for environments involving ignitable fibers or flyings.
Additional Protection and Standards
-
UL 844 — Hazardous Locations.
-
UL 1598 — Luminaires.
-
NEMA 4X.
-
IP66.
-
IK10 with wire guard.
-
3G vibration.
-
ABS.
These classifications make the EX-HTA Series relevant to specialized industrial applications requiring documented hazardous-location equipment.
Driverless LED Technology and Thermal Management
The EX-HTA uses a driverless integrated-circuit design to support compact construction and elevated-temperature performance.
The manufacturer combines this electrical architecture with an aluminum housing designed for effective heat dissipation.
Reduced Component Complexity
The driverless design eliminates the conventional separate LED driver architecture, supporting a more compact fixture arrangement.
High-Temperature Operation
The fixture is engineered to maintain illumination in elevated-temperature industrial environments, with maximum ambient ratings determined by the selected wattage and fixture length.
Efficient LED Performance
The manufacturer specifies 130 lumens per watt across the EX-HTA Series.
This supports energy-efficient lighting in applications where high-temperature operating requirements limit conventional fixture choices.
Industrial Applications
Steel Mills and Metallurgical Facilities
Steel processing, foundries, and metallurgical operations can expose lighting equipment to elevated ambient temperatures, dust, and vibration.
The EX-HTA provides specialized linear illumination for appropriate classified locations in these demanding facilities.
Petrochemical Processing Facilities
Petrochemical operations may require lighting that addresses both hazardous-location classifications and elevated operating temperatures.
The EX-HTA Series offers Class I Division 2 configurations for designated process environments.
Chemical Processing Plants
Chemical production and processing facilities often require durable fixtures with resistance to moisture, dust, and corrosive conditions.
The EX-HTA combines hazardous-location construction with an IP66 and NEMA 4X enclosure design.
Power Plants
Power generation facilities can include elevated-temperature equipment areas, service platforms, and industrial maintenance spaces.
The EX-HTA provides linear LED lighting for compatible high-temperature and classified locations.
Wastewater Treatment Facilities
Wastewater treatment plants may include moisture, corrosive atmospheres, and designated hazardous locations.
The series offers protected aluminum construction and flexible mounting arrangements for applicable facility areas.
Paper Mills
Paper processing facilities may require robust industrial lighting for production areas, equipment platforms, and elevated-temperature environments.
Offshore and Heavy Industrial Facilities
Offshore installations, heavy industrial storage facilities, and loading platforms can expose lighting equipment to vibration, moisture, and corrosive conditions.
The EX-HTA’s protected construction supports lighting projects with these environmental requirements.
For additional facility lighting categories, explore our industrial lighting fixtures for manufacturing, processing, and infrastructure applications.
2-Foot and 4-Foot Linear Configurations
The EX-HTA is available in two lengths to accommodate different equipment layouts and mounting conditions.
HTA2 — Compact 2-Foot Fixture
The HTA2 is approximately 24.06 inches long.
Its compact design supports smaller process areas, equipment platforms, and installations where available mounting space is limited.
Available wattages: 20W, 30W, 40W, and 50W.
HTA4 — Extended 4-Foot Fixture
The HTA4 is approximately 46.25 inches long.
The extended configuration provides a larger range of lumen packages and supports illumination along equipment rows, work platforms, and industrial circulation areas.
Available wattages: 10W, 20W, 30W, 40W, 50W, 60W, 80W, and 100W.
Optical Performance and Color Temperature
The EX-HTA Series features a frosted glass diffuser and a nominal 120° beam angle.
This broad distribution supports general industrial illumination across work areas, equipment platforms, and circulation routes.
Color Temperature Options
The manufacturer’s ordering guide identifies:
-
1700K
-
2700K
-
3000K
-
5700K
-
6000K
-
6500K
-
7500K
The series has a CRI greater than 70.
Available color temperatures allow lighting designers to select an appropriate light appearance for industrial operating conditions.
Mounting Options
The EX-HTA supports three installation arrangements.
U-Bracket Mounting — Included
The standard U-bracket allows the fixture to be mounted directly to a suitable supporting structure.
This option is useful for equipment platforms, industrial ceilings, and fixed structural installations.
Pole Mounting — Optional
An optional pole mounting assembly allows the luminaire to be positioned on a compatible support.
The manufacturer’s drawings show an angled pole-mounted arrangement with a 3/4-inch NPT connection.
Pendant Mounting — Optional
Optional suspension hardware supports hanging the fixture from overhead structural supports.
Pendant mounting can be useful where the lighting must be positioned below elevated structural members.
Industrial Construction and Protection
The EX-HTA uses materials selected for demanding industrial conditions.
| Component | Construction |
|---|---|
| Main Housing | Die-Cast Aluminum |
| Diffuser | Frosted Glass |
| Hardware | Stainless Steel 304 |
| Gasket | Silicone Rubber |
| Cable Entry | 3/4-inch NPT |
| Ingress Protection | IP66 |
| Impact Protection | IK10 with Wire Guard |
| Enclosure Designation | NEMA 4X |
The aluminum housing supports thermal management, while the frosted glass diffuser provides broad LED illumination.
Stainless steel hardware and protected construction support operation in industrial environments exposed to moisture, dust, and vibration.
Technical Specifications
| Specification | VENAS EX-HTA |
|---|---|
| Manufacturer | VENAS |
| Series | EX-HTA |
| Product Type | High-Temperature Explosion-Proof LED Linear Light |
| Fixture Lengths | HTA2 / HTA4 |
| HTA2 Wattages | 20W / 30W / 40W / 50W |
| HTA4 Wattages | 10W / 20W / 30W / 40W / 50W / 60W / 80W / 100W |
| Lumen Range | 1,300–13,000 lm |
| Luminous Efficacy | 130 lm/W |
| Input Voltage | 120–277V AC |
| Input Frequency | 50/60Hz |
| Power Factor | Greater Than 0.95 at 120V |
| Dimming | Non-Dimming |
| CRI | Greater Than 70 |
| Beam Angle | 120° |
| LED Type | Surface-Mount 2835 |
| Driver Design | Driverless IC |
| Maximum Ambient Temperature | Up to +110°C, Model Dependent |
| Minimum Ambient Temperature | −40°C |
| Hazardous Location | Class I Division 2, Groups A–D |
| Combustible Dust | Class II Division 2, Groups F–G |
| Additional Classification | Class III |
| Standards | UL 844 / UL 1598 |
| Ingress Protection | IP66 |
| Enclosure Designation | NEMA 4X |
| Impact Rating | IK10 with Wire Guard |
| Vibration Rating | 3G |
| Housing | Die-Cast Aluminum |
| Diffuser | Frosted Glass |
| Hardware | Stainless Steel 304 |
| Cable Entry | 3/4-inch NPT |
| Included Mount | U-Bracket |
| Optional Mounts | Pole / Pendant |
| Stated Service Life | Up to 50,000 Hours |
| Salt Spray Test | 500 Hours |
| Fixture Warranty | 1-Year Limited |
Dimensions and Weight
| Dimension | HTA2 | HTA4 |
|---|---|---|
| Approximate Fixture Length | 24.06 in. | 46.25 in. |
| Net Weight | 5.40 lb | 10.80 lb |
| Gross Shipping Weight | 7.47 lb | 15.21 lb |
| Quantity per Carton | 1 | 1 |
The manufacturer provides detailed dimensional drawings for both fixture lengths, including mounting-hole positions and U-bracket arrangements.
Buyer Questions
Which EX-HTA model operates at 110°C?
The HTA4 10W and 20W configurations have a maximum listed ambient temperature of 110°C.
Are all wattages rated for the same temperature?
No. Maximum ambient temperature varies by wattage and fixture length. The HTA2 ranges from 85°C to 105°C, while the HTA4 ranges from 80°C to 110°C.
Is the EX-HTA suitable for Class I Division 2 locations?
Yes. The manufacturer identifies Class I Division 2, Groups A, B, C, and D.
Does the fixture support combustible-dust locations?
The series is identified for Class II Division 2, Groups F and G, as well as Class III locations.
Is a mounting bracket included?
Yes. The U-bracket is included. Pole and pendant mounting accessories are available separately.
What is the maximum lumen output?
The HTA4 100W configuration provides 13,000 lumens.
Does the fixture support dimming?
The manufacturer’s ordering guide identifies a non-dimming configuration.
High-Temperature Explosion-Proof Linear Lighting for Your Facility
The EX-HTA Series combines hazardous-location protection, high-temperature capability, and efficient linear LED illumination for demanding industrial applications.
With 2-foot and 4-foot models, multiple wattages, and maximum ambient ratings up to 110°C, the EX-HTA offers flexible lighting configurations for specialized industrial facilities.
LED PROS WorldWide provides commercial project quotations and technical product selection assistance for contractors, engineers, plant operators, and industrial facility managers.
Request a Project Quote or call 1-844-533-7767.
Provide the hazardous-location classification, ambient temperature, fixture quantity, wattage, mounting configuration, and project requirements.
Frequently Asked Questions
What is the EX-HTA?
The EX-HTA is a high-temperature, hazardous-location LED linear lighting series available in 2-foot and 4-foot configurations.
What is the highest ambient temperature rating?
Selected HTA4 models are rated for ambient temperatures up to 110°C (230°F).
What wattages are available?
The HTA2 offers 20W–50W configurations, while the HTA4 offers 10W–100W configurations.
How many lumens do the fixtures produce?
The series provides approximately 1,300–13,000 lumens, depending on wattage.
Is the fixture explosion-proof?
The manufacturer identifies the EX-HTA as a hazardous-location luminaire complying with UL 844 and classified for Class I Division 2, Class II Division 2, and Class III locations.
Is the EX-HTA rated for Class I Division 1?
The manufacturer specifies Class I Division 2, not Class I Division 1.
What is the ingress protection rating?
The fixture is rated IP66.
What mounting options are available?
U-bracket, pole, and pendant mounting configurations are offered.
What voltage does the EX-HTA use?
The series operates on 120–277V AC.
What warranty is included?
The manufacturer specifies a one-year limited fixture warranty.
Stay Connected with Our Lighting Resources
Add IndustrialLightingFixtures.org as a Preferred Source on Google to see more of our lighting guides and technical resources across Google Search experiences.
Related Resources
Explosion-Proof Linear Lighting — Explore hazardous-location LED linear fixtures for chemical processing, industrial manufacturing, equipment platforms, and classified work areas.
High-Temperature LED High Bay Lights — Compare LED high bay lighting solutions engineered for elevated-temperature industrial environments and demanding manufacturing facilities.
LED Explosion-Proof Lighting — Discover hazardous-location LED lighting options for classified industrial facilities, including high bays, linear fixtures, floodlights, and specialized equipment lighting.
Industrial Lighting — Explore commercial and industrial LED lighting fixtures for factories, warehouses, processing facilities, and heavy industrial infrastructure.