From $98
Request an LED Edge-Lit Exit Sign Quote
Specifying emergency exit signage for a commercial building, office complex, school, hospital, retail facility, or industrial property?
Request a Quote or call 1-844-533-7767 for commercial pricing, availability, and product assistance.
Include your project location, required quantity, voltage, mounting configuration, and exit signage requirements.
Explore our commercial emergency LED exit signs for additional illuminated exit signage and emergency egress lighting solutions.
The LS-GL037R LED Edge-Lit Emergency Exit Sign provides illuminated exit identification for commercial, institutional, and industrial buildings requiring dependable emergency egress signage. Featuring red LED lettering, a slim aluminum housing, and a clear edge-lit sign panel, the fixture delivers uniform illumination without noticeable shadows or hot spots. Its 4W input power, 120–347V AC operating range, and rechargeable nickel-cadmium battery make it a practical option for both new construction and existing building upgrades.
Designed with 8-inch EXIT lettering and a stated 100-foot viewing distance based on UL 924 standards, the LS-GL037R is also identified as New York City approved. The sign supports wall, ceiling, and end mounting configurations, providing installation flexibility for corridors, building exits, and interior circulation areas. This low-profile fixture complements our selection of LED emergency exit signs and commercial egress lighting for projects requiring illuminated exit identification and battery-backed operation.
Low-Profile LED Edge-Lit Exit Sign Design
The LS-GL037R uses an edge-lit design that illuminates the EXIT lettering through a clear sign panel.
Its slim aluminum housing provides a clean architectural appearance for commercial and institutional interiors.
Key Features
-
Red LED EXIT lettering.
-
Edge-lit sign panel.
-
Uniform illumination without shadows or hot spots.
-
4W input power.
-
120–347V AC, 50/60Hz.
-
1W listed LED output power.
-
Eight red LEDs.
-
Rechargeable 3.6V, 600mAh Ni-Cd battery.
-
Emergency operating duration greater than 120 minutes.
-
24-hour battery recharge time.
-
8-inch EXIT lettering with 1-inch strokes.
-
Stated 100-foot viewing distance.
-
New York City approved, as identified in the product documentation.
-
Aluminum housing.
-
Wall, ceiling, and end mounting options.
-
Single- and double-face mounting arrangements described in the installation instructions.
-
Integrated test switch and AC status indicator on self-powered configurations.
-
Compact 13.7 × 10.47 × 1.81-inch dimensions.
Red LED EXIT Lettering with Edge-Lit Illumination
The LS-GL037R features red illuminated EXIT lettering designed to provide visible directional guidance toward designated building exits.
Uniform Letter Illumination
The edge-lit design distributes light across the sign graphics to reduce shadows and hot spots.
Eight Red LEDs
The published electrical specifications identify eight red LEDs with a listed output wattage of 1W.
8-Inch Letter Height
The EXIT lettering measures 8 inches high with 1-inch strokes.
100-Foot Viewing Distance
The product documentation identifies a 100-foot viewing distance based on UL 924 standards.
Directional Arrow Graphics
The illustrated sign includes directional arrow markings on both sides of the EXIT lettering.
More Than 120 Minutes of Emergency Battery Operation
The LS-GL037R incorporates a rechargeable nickel-cadmium battery for emergency operation during an interruption of normal electrical power.
Emergency Battery Specifications
| Specification | Rating |
|---|---|
| Battery Chemistry | Nickel-Cadmium (Ni-Cd) |
| Battery Voltage | 3.6V |
| Battery Capacity | 600mAh |
| Emergency Duration | Greater Than 120 Minutes |
| Recharge Time | 24 Hours |
| LED Output Power | 1W |
Automatic Emergency Operation
The internally self-powered configuration switches to battery operation when normal AC power is interrupted.
Battery Recharge
The battery requires approximately 24 hours to recharge.
The installation instructions specify allowing at least 24 hours of charging after initial electrical connection before normal operation.
Integrated Test Switch
The self-powered configuration includes a test switch for checking emergency battery operation.
When the test switch is pressed, the AC indicator turns off and the LEDs operate from battery power.
Releasing the switch returns the LEDs to AC operation.
120–347V AC Input for Commercial Buildings
The LS-GL037R supports a broad AC input voltage range.
Electrical Characteristics
| Specification | Rating |
|---|---|
| Input Voltage | 120–347V AC |
| Frequency | 50/60Hz |
| Input Wattage | 4W |
| Input Current | 0.06A |
| Listed Power Factor | 0.96 |
| LED Output Power | 1W |
| LED Quantity | 8 Red LEDs |
The 347V capability is particularly relevant to commercial and institutional buildings using compatible higher-voltage lighting circuits.
Additional Wiring Configuration
The installation diagrams also illustrate an AC/DC configuration with a 6–24V DC input.
The available DC wiring arrangement should be matched to the specific ordered configuration.
Aluminum Housing and Architectural Edge-Lit Construction
The LS-GL037
Aluminum Housing and Architectural Edge-Lit Construction
The LS-GL037R uses an aluminum housing with a suspended edge-lit sign panel.
Slim Housing
The upper enclosure has a low-profile design suitable for commercial interiors.
Clear Sign Panel
The transparent panel provides illuminated EXIT lettering while maintaining a relatively unobtrusive appearance.
Red Lettering
Red EXIT lettering provides visual identification of designated building exits.
Compact Construction
The fixture measures 13.7 inches wide, 10.47 inches high, and 1.81 inches deep.
Wall, Ceiling, and End Mounting Options
The LS-GL037R installation instructions describe multiple mounting arrangements.
Wall Surface Mounting
The sign can be mounted directly to a compatible electrical junction box using the supplied mounting provisions.
Ceiling Mounting
A ceiling canopy arrangement allows the sign to hang below an overhead junction box.
End Mounting
The sign can be mounted perpendicular to a wall using the end mounting arrangement.
This configuration is useful where the sign must be visible along a corridor or interior passageway.
Single- and Double-Face Arrangements
The installation instructions describe ceiling and end mounting for single- or double-face configurations.
Universal Mounting Hardware
The installation diagrams illustrate a universal spider plate and canopy hardware for compatible junction boxes.
Conduit Connections
The fixture includes top and side conduit knockouts for applicable surface-wiring arrangements.
New York City Emergency Exit Sign Applications
The product documentation identifies the LS-GL037R as New York City approved.
Its 8-inch lettering, 1-inch letter strokes, and 100-foot stated viewing distance are particularly relevant to projects requiring larger illuminated exit signage.
The specification describes the product as suitable for New York applications where larger exit lettering and emergency operation are required.
The exact approval and configuration should be matched to the project’s applicable building and electrical requirements.
Commercial and Institutional Applications
Office Buildings
Edge-lit exit signs provide illuminated egress identification for corridors, common areas, and designated building exits.
Schools and Universities
Educational facilities require visible exit identification across classrooms, hallways, assembly spaces, and administrative buildings.
Hospitals and Healthcare Facilities
Healthcare properties use illuminated exit signage to identify designated egress routes throughout patient care and support areas.
Hotels and Hospitality Properties
The slim edge-lit design is suitable for guest corridors, common areas, and interior circulation spaces.
Retail Stores and Shopping Centers
Commercial retail properties require illuminated exit identification for customer and employee egress routes.
Municipal and Government Buildings
Public facilities may require battery-backed LED exit signage with suitable mounting and visibility characteristics.
Commercial Warehouses
The LS-GL037R can provide exit identification in appropriate indoor warehouse offices, corridors, and personnel access areas.
Industrial Facility Interiors
Industrial properties may use edge-lit emergency exit signs in suitable non-hazardous offices, control rooms, and interior egress routes.
For additional commercial and industrial facility solutions, explore our industrial lighting fixtures for warehouses, manufacturing facilities, and commercial properties.
Installation and Maintenance
The LS-GL037R is designed for installation by qualified electrical personnel.
Unswitched Electrical Supply
The installation instructions specify connecting the fixture to an unswitched, continuously available AC supply.
Initial Battery Charging
The rechargeable battery should be charged for at least 24 hours after initial installation.
Emergency Function Testing
The self-powered configuration includes a test switch for checking emergency operation.
The maintenance instructions call for periodic testing and written maintenance records in accordance with applicable requirements.
Indoor Installation
The product instructions explicitly state that the fixture must not be used outdoors.
Cleaning
The sign panel should be cleaned regularly to maintain visibility.
Abrasive materials and solvents should not be used.
Fixture Dimensions
| Dimension | Specification |
|---|---|
| Width | 13.7 in. |
| Height | 10.47 in. |
| Depth | 1.81 in. |
| EXIT Letter Height | 8 in. |
| Letter Stroke | 1 in. |
| Stated Viewing Distance | 100 ft |
| Housing Material | Aluminum |
Technical Specifications
| Specification | LS-GL037R |
|---|---|
| Product Type | Edge-Lit LED Emergency Exit Sign |
| Model | LS-GL037R |
| Sign Color | Red |
| Illumination | LED Edge-Lit |
| LED Quantity | 8 Red LEDs |
| Input Power | 4W |
| LED Output Power | 1W |
| Input Current | 0.06A |
| Listed Power Factor | 0.96 |
| AC Input Voltage | 120–347V |
| AC Frequency | 50/60Hz |
| DC Wiring Option Illustrated | 6–24V DC |
| Battery Chemistry | Ni-Cd |
| Battery Voltage | 3.6V |
| Battery Capacity | 600mAh |
| Emergency Duration | Greater Than 120 Minutes |
| Recharge Time | 24 Hours |
| Letter Height | 8 in. |
| Letter Stroke | 1 in. |
| Viewing Distance | 100 ft, Stated |
| Housing Material | Aluminum |
| Mounting | Wall / Ceiling / End |
| Mounting Configurations | Single / Double Face Described |
| Test Switch | Self-Powered Configuration |
| AC Status Indicator | Self-Powered Configuration |
| New York City Approval | Identified in Product Documentation |
| UL 924 | Referenced in Product Documentation |
| Fixture Width | 13.7 in. |
| Fixture Height | 10.47 in. |
| Fixture Depth | 1.81 in. |
| Installation Environment | Indoor |
Buyer Questions
What makes the LS-GL037R different from a conventional box-style exit sign?
The edge-lit design uses a clear sign panel and slim aluminum housing rather than a fully enclosed rectangular sign cabinet.
Does the sign provide emergency battery backup?
Yes. The LS-GL037R includes a rechargeable Ni-Cd battery with a specified emergency duration greater than 120 minutes.
Is the exit sign suitable for 347V electrical systems?
Yes. The published AC input range is 120–347V.
Can the sign be mounted to a wall or ceiling?
Yes. Wall, ceiling, and end mounting arrangements are described.
Is the LS-GL037R identified as New York City approved?
Yes. The product documentation identifies New York City approval.
What is the viewing distance?
The stated viewing distance is 100 feet.
Does the sign include a test switch?
The internally self-powered configuration includes a test switch and AC status indicator.
Is the fixture intended for outdoor installation?
No. The installation instructions specify indoor use.
Specify LS-GL037R Edge-Lit Exit Signs for Your Building
The LS-GL037R combines a low-profile architectural design with red LED exit identification, 120–347V operation, and more than two hours of emergency battery backup.
With 8-inch EXIT lettering, multiple mounting arrangements, and New York City approval identified in the product documentation, this edge-lit sign provides an option for commercial, institutional, and industrial building projects.
LED PROS WorldWide provides commercial project quotations and product assistance for electrical contractors, facility managers, engineers, and purchasing departments.
Request an LS-GL037R Exit Sign Quote or call 1-844-533-7767.
Include the required quantity, voltage, mounting configuration, building location, and project specifications.
Frequently Asked Questions
What is the LS-GL037R?
The LS-GL037R is an edge-lit LED emergency exit sign featuring red EXIT lettering and rechargeable battery backup.
What is the input wattage?
4W.
What voltage does it support?
120–347V AC, 50/60Hz.
What is the emergency operating duration?
Greater than 120 minutes.
What battery does the sign use?
A rechargeable 3.6V, 600mAh nickel-cadmium battery.
How long does the battery take to recharge?
Approximately 24 hours.
How tall are the EXIT letters?
8 inches, with 1-inch strokes.
What is the stated viewing distance?
100 feet.
Is the sign New York City approved?
The product documentation identifies New York City approval.
What mounting options are available?
Wall, ceiling, and end mounting.
Does the sign include a test switch?
The self-powered configuration includes a test switch for checking battery operation.
Can the LS-GL037R be installed outdoors?
No. The installation instructions specify that it must not be used outdoors.
Stay Connected with Our Lighting Resources
Add IndustrialLightingFixtures.org as a Preferred Source on Google to see more of our lighting guides and technical resources across Google Search experiences.
Related Resources
Emergency LED Exit Signs — Explore illuminated LED exit signs and emergency egress lighting for commercial, institutional, and industrial buildings.
Explosion-Proof LED Exit Signs — Compare specialized exit signs and emergency lighting for classified industrial environments requiring hazardous-location protection.
Industrial Lighting — Browse commercial and industrial LED lighting fixtures for warehouses, manufacturing facilities, and building infrastructure.