From $350
Request a Class I Division 2 LED Lighting Quote
Planning lighting for a petrochemical plant, industrial processing facility, refinery, manufacturing operation, or other classified hazardous location?
Request a Quote or call 1-844-533-7767 for commercial pricing, availability, and product selection assistance.
Provide the hazardous-location classification, mounting height, required wattage, voltage, fixture quantity, and project specifications.
Explore our Class I Division 2 LED lighting for additional hazardous-location lighting solutions.
The FY Lighting Class I Division 2 Explosion-Proof LED Light Series provides high-efficiency illumination for industrial environments requiring hazardous-location-rated lighting equipment. Available in round and rectangular configurations, the FYS, FYD, FFS, and FFD series offer wattages from 20W to 200W, lumen outputs from 3,000 to 30,000 lumens, and efficacy up to 150 lumens per watt. Multiple beam distributions, mounting configurations, and voltage options support a broad range of industrial lighting projects.
Engineered for demanding operating conditions, these fixtures combine Class I Division 2, Class II Division 2, and Class III hazardous-location classifications with IP66 ingress protection, IK10 impact resistance, and a five-year warranty. The product family expands our selection of Class I Division 2 explosion-proof lighting fixtures for contractors, engineers, and facility managers specifying reliable industrial illumination.
Explosion-Proof LED Lighting for Hazardous Industrial Locations
FY Lighting’s explosion-proof LED fixtures are designed for classified industrial environments where lighting equipment must meet specific hazardous-location requirements.
The series combines efficient LED performance with sealed construction, durable lenses, and multiple mounting options.
Key Features
-
Four series: FYS, FYD, FFS, and FFD.
-
Round and rectangular fixture configurations.
-
Wattages from 20W to 200W.
-
Lumen output from 3,000 to 30,000 lumens.
-
Luminous efficacy up to 150 lm/W.
-
Class I Division 2, Groups A, B, C, and D.
-
Class II Division 2, Groups F and G.
-
Class III hazardous-location classification.
-
IP66 ingress protection.
-
IK10 impact protection.
-
100–277V AC and 200–480V AC voltage options.
-
Operating temperatures from −40°C to +65°C.
-
CRI 70 and 80 options.
-
Beam angles of 25°, 60°, 90°, and 110°.
-
Multiple mounting configurations.
-
90-minute emergency lighting option listed by the manufacturer.
-
L70 rated life exceeding 100,000 hours.
-
Five-year warranty.
Four Fixture Series for Different Lighting Applications
FY Lighting offers two round fixture series and two rectangular fixture series.
FYS Series — Compact Round Explosion-Proof LED Lights
<escape></escape>20W–80W | 3,000–12,000 Lumens<escape></escape>
The FYS Series features a compact round housing suited to hazardous-location applications requiring moderate lumen output.
Its design supports overhead lighting, equipment areas, maintenance spaces, and industrial platforms.
Available wattages:
20W, 40W, 50W, 60W, 70W, and 80W.
The FYS Series is appropriate for facilities requiring compact, efficient hazardous-location lighting with flexible mounting arrangements.
FYD Series — High-Output Round Explosion-Proof LED Lights
<escape></escape>100W–200W | 15,000–30,000 Lumens<escape></escape>
The FYD Series provides higher-output illumination in a larger round fixture configuration.
Designed for industrial applications requiring greater light levels, the series supports overhead mounting in processing facilities, production areas, and elevated industrial workspaces.
Available wattages:
100W, 120W, 150W, 160W, 180W, and 200W.
FFS Series — Compact Rectangular Explosion-Proof LED Flood Lights
<escape></escape>20W–80W | 3,000–12,000 Lumens<escape></escape>
The FFS Series features a rectangular housing for directional lighting applications.
Its configuration is suited to equipment platforms, industrial work areas, process structures, and other locations where targeted illumination is required.
Available wattages:
20W, 40W, 50W, 60W, 70W, and 80W.
FFD Series — High-Output Rectangular Explosion-Proof LED Flood Lights
<escape></escape>100W–200W | 15,000–30,000 Lumens<escape></escape>
The FFD Series provides higher-output illumination in a rectangular fixture design.
The series supports applications requiring directional lighting over larger work areas, equipment installations, and industrial operating spaces.
Available wattages:
100W, 120W, 130W, 150W, 160W, 180W, and 200W.
Model Comparison
| Series | Fixture Design | Wattage Range | Lumen Output | Maximum Efficacy |
|---|---|---|---|---|
| FYS | Round | 20W–80W | 3,000–12,000 lm | 150 lm/W |
| FYD | Round | 100W–200W | 15,000–30,000 lm | 150 lm/W |
| FFS | Rectangular | 20W–80W | 3,000–12,000 lm | 150 lm/W |
| FFD | Rectangular | 100W–200W | 15,000–30,000 lm | 150 lm/W |
The four series provide a choice of fixture shapes and lumen packages while sharing the same general electrical, environmental, and hazardous-location specifications.
Hazardous-Location Classifications
Class I, Division 2 — Groups A, B, C, and D
The FYS, FYD, FFS, and FFD series are specified for Class I Division 2 locations involving flammable gases or vapors.
These applications may include designated areas of petrochemical facilities, refineries, chemical processing plants, and industrial manufacturing operations.
Class II, Division 2 — Groups F and G
The fixtures are also identified for Class II Division 2 locations involving combustible dust.
This classification is relevant to designated industrial processing and material-handling environments.
Class III
The manufacturer additionally identifies Class III hazardous-location classification for environments involving ignitable fibers or flyings.
Environmental Protection
The fixtures feature:
-
IP66 protection against dust ingress and powerful water jets.
-
IK10 impact resistance.
-
UL 844 hazardous-location certification indicated by the manufacturer.
-
RoHS compliance.
These features support industrial lighting installations exposed to challenging environmental conditions.
High-Efficiency LED Performance
FY Lighting specifies luminous efficacy up to 150 lumens per watt across the four series.
This allows the fixtures to provide substantial illumination while reducing electrical consumption compared with less efficient lighting technologies.
Lumen Packages
The compact FYS and FFS configurations provide 3,000–12,000 lumens.
The higher-output FYD and FFD configurations provide 15,000–30,000 lumens.
Long Service Life
The manufacturer specifies an L70 rated life exceeding 100,000 hours.
This supports applications where access for lighting maintenance may be difficult or require scheduled industrial shutdowns.
Optical Performance
Available beam angles include:
-
25°: Narrow distribution for concentrated illumination.
-
60°: Medium distribution for focused industrial lighting.
-
90°: Wide distribution for general work-area illumination.
-
110°: Broad distribution for larger coverage areas.
Beam selection allows lighting designers to match the fixture to mounting height, target area, and required illumination.
Industrial Applications
Petrochemical Processing Facilities
Hazardous-location LED fixtures are frequently specified for classified process areas, maintenance platforms, and equipment installations.
The FY Lighting series provides multiple wattages and beam distributions for these industrial applications.
Oil and Gas Facilities
Oil and gas processing facilities may require lighting for classified work areas, service platforms, and production infrastructure.
The fixtures provide Class I Division 2 configurations with durable construction and multiple mounting options.
Chemical Manufacturing Plants
Chemical processing operations often require lighting equipment designed for designated hazardous locations.
The FY Lighting series supports both general overhead illumination and directional lighting applications.
Industrial Manufacturing Facilities
Manufacturing facilities may include classified production areas, equipment platforms, and industrial service spaces.
The round and rectangular configurations allow different lighting layouts to be developed around equipment and work areas.
Wastewater Treatment Facilities
Selected wastewater treatment areas may require hazardous-location-rated equipment.
IP66 construction and multiple mounting options make these fixtures relevant to compatible facility installations.
Industrial Storage and Material Handling
Hazardous-location lighting may be required in designated industrial storage, processing, and material-handling environments.
The series provides compact and higher-output fixture options for different lighting requirements.
Explore our complete range of industrial LED lighting fixtures for additional manufacturing, processing, and infrastructure applications.
Voltage Options for Industrial Electrical Systems
The FY Lighting series offers two input voltage ranges:
-
100–277V AC.
-
200–480V AC.
These voltage options support a range of commercial and industrial electrical systems, including facilities operating at higher distribution voltages.
The appropriate voltage configuration can be selected during project specification.
Mounting Configurations
The manufacturer lists six mounting options across the four series.
Pendant Mounting
Supports overhead installation from suitable suspended mounting assemblies.
Yoke Mounting
Provides an adjustable bracket configuration for directional fixture positioning.
Ceiling Mounting
Supports direct overhead installation where appropriate mounting structures are available.
Stanchion Mounting
Provides an option for installation on industrial stanchion supports.
Wall Mounting
Supports installation on vertical structures and equipment-area walls.
Pole Mounting
Allows installation on compatible pole-mounted supports.
The available mounting arrangements provide flexibility for new construction, replacement installations, and industrial lighting retrofits.
Engineered LED Driver and Durability
FY Lighting describes a fully sealed, thermally protected LED driver designed to resist dust, moisture, and vibration.
The manufacturer also reports accelerated life testing exceeding five years of continuous 24-hour operation and a driver mean time between failures exceeding 150,000 hours.
These design features support long-term operation in industrial environments where lighting reliability is important.
Tempered Glass and Lens Options
The FYS and FYD series specify tempered glass lenses.
The FFS and FFD series list tempered glass and polycarbonate lens materials.
Emergency Lighting
The manufacturer identifies a 90-minute emergency lighting option for the product family.
This provides an additional configuration consideration for projects requiring emergency illumination.
Technical Specifications
| Specification | FYS / FYD / FFS / FFD |
|---|---|
| Manufacturer | FY Lighting |
| Product Family | Explosion-Proof LED Light |
| Series | FYS, FYD, FFS, FFD |
| Fixture Designs | Round / Rectangular |
| Wattage Range | 20W–200W |
| Lumen Output | 3,000–30,000 lm |
| Maximum Efficacy | 150 lm/W |
| Input Voltage | 100–277V AC / 200–480V AC |
| CRI | 70 / 80 |
| Beam Angles | 25° / 60° / 90° / 110° |
| Operating Temperature | −40°C to +65°C |
| Class I | Division 2, Groups A–D |
| Class II | Division 2, Groups F–G |
| Class III | Listed |
| Hazardous-Location Standard | UL 844 |
| Ingress Protection | IP66 |
| Impact Protection | IK10 |
| Lens — FYS / FYD | Tempered Glass |
| Lens — FFS / FFD | Tempered Glass / Polycarbonate |
| Mounting | Pendant, Yoke, Ceiling, Stanchion, Wall, Pole |
| Emergency Option | 90 Minutes |
| Rated Life | L70 Greater Than 100,000 Hours |
| Warranty | 5 Years |
| Environmental Compliance | RoHS |
Fixture Dimensions
The manufacturer provides dimensional drawings for each series.
| Series | Dimensions Shown |
|---|---|
| FYS | 308 mm width; 166 mm / 133 mm vertical dimensions |
| FYD | 358 mm width; 157.4 mm / 89.5 mm vertical dimensions |
| FFS | 320 × 200 mm face; 93 mm depth |
| FFD | 390 × 288 mm face; 142.4 mm depth |
Refer to the manufacturer’s dimensional drawings when planning mounting clearances and installation arrangements.
Buyer Questions
Which series should be selected for high-bay applications?
The round FYS and FYD series are suitable candidates for overhead industrial lighting. The FYD provides higher lumen output for applications requiring greater illumination.
Which series is better suited to directional floodlighting?
The rectangular FFS and FFD series offer directional fixture configurations, with the FFD providing higher-output options.
Are 480V configurations available?
Yes. The manufacturer lists a 200–480V AC voltage option.
What is the maximum lumen output?
The FYD and FFD series provide up to 30,000 lumens.
Can the fixtures operate in high ambient temperatures?
The manufacturer specifies an operating range from −40°C to +65°C.
Are multiple beam angles available?
Yes. Available beam angles include 25°, 60°, 90°, and 110°.
Are emergency configurations offered?
The manufacturer lists a 90-minute emergency lighting option.
Specify FY Lighting Explosion-Proof LED Fixtures for Your Project
The FY Lighting FYS, FYD, FFS, and FFD series provide flexible hazardous-location lighting solutions for industrial facilities requiring efficient, durable LED illumination.
With round and rectangular configurations, wattages from 20W to 200W, multiple beam distributions, and voltage options up to 480V, the series supports a broad range of commercial and industrial project requirements.
LED PROS WorldWide provides project quotations and product selection assistance for contractors, engineers, industrial facility managers, and purchasing departments.
Request a Quote or call 1-844-533-7767.
Include your hazardous-location classification, voltage, mounting height, required lumen output, fixture quantity, and preferred mounting configuration.
Frequently Asked Questions
What are FY Lighting Class I Division 2 explosion-proof LED lights?
They are hazardous-location LED luminaires available in four round and rectangular fixture series for industrial lighting applications.
What wattages are available?
The product family includes configurations from 20W to 200W.
What is the maximum lumen output?
The higher-output FYD and FFD series provide up to 30,000 lumens.
Are the fixtures rated for Class I Division 2?
Yes. The individual series specifications identify Class I Division 2, Groups A, B, C, and D.
Are they suitable for combustible-dust locations?
The manufacturer identifies Class II Division 2, Groups F and G, along with Class III classifications.
What voltage options are offered?
100–277V AC and 200–480V AC.
What is the operating temperature range?
−40°C to +65°C.
What is the IP rating?
IP66.
What is the rated service life?
The manufacturer specifies L70 greater than 100,000 hours.
What warranty is provided?
Five years.
Stay Connected with Our Lighting Resources
Add IndustrialLightingFixtures.org as a Preferred Source on Google to see more of our lighting guides and technical resources across Google Search experiences.
Related Resources
Class I Division 2 LED Lighting — Explore hazardous-location LED fixtures designed for Class I Division 2 industrial environments involving flammable gases and vapors.
LED Explosion-Proof Lighting — Compare explosion-proof and hazardous-location LED lighting options for industrial processing, chemical manufacturing, and classified facilities.
Industrial Lighting — Discover industrial LED lighting fixtures for manufacturing plants, processing operations, warehouses, and infrastructure facilities.